Configuring COFDM output modules
14
4. Check the Select service/s checkbox for the required services.
5. (Optional) Specify an Output SID for the selected services.
6. (Optional) Specify a collective name (Mux) for the selected services in the Mux
name field.
7. Press the OK button.
Note that services that have been selected will no longer be available in the TDX
pool for other output modules.
From input module
1. Select ‘Transparent’ in the Select input drop-down list.
The Select input window is displayed.
2. Check the Selected checkbox for the required input module.
3. Press the OK button.
All the services that are active on the input module will be transmitted via the
output module.
Additional settings
1. Make (if required) additional configuration changes in the following fields/drop
down lists in the configuration window:
RF level correction.
Modulation
FEC rate
Guard interval