Configuring COFDM output modules
13
The first time the output configuration is opened, it will contain default and/or
empty values, and the output module is disabled.
3. Remove the check from the Disabled output checkbox.
Channel, channel spacing
and frequency
COFDM modules can be configured either by using the pre-defined channel plans,
or through manual specification.
Pre-defined 1. Select the required Channel plan.
2. Select the required Channel.
Pre-defined values are loaded in the Frequency and Channel spacing fields.
Manual 1. Select ‘Frequency’ in the Channel drop-down list.
2. Enter the desired frequency (MHz) in the Frequency field.
3. Select the required channel spacing in the channel spacing drop-down list.
Select input
Input can be selected for the output module in two ways:
From the TDH Pool
From a selected input module.
From TDH Pool
1. Press the Services button.
2. Select ‘Services’ in the Select input drop-down list.
3. Press the Services button.
The Select services window is displayed.
Uncheck
Configuring COFDM output modules
12
Configuring COFDM output modules
Pre-requisites
The headend is running, the output module is in position, and the TDH Service Tool
is connected to the headend.
See the TDH 800 Headend User Guide for information on inserting the output
module into the TDH 800 headend.
Configuration
1. Select the Output tab in the TDH Service Tool.
2. Press the Setup button for the first output row.