- 43 -
CCS-2 1002
6
f
inal
ProCedures
After installing the head-end station, upgrading accessories or installing cas-
settes it is necessary to tighten all cable connections, cable terminals and cover
screws in order to maintain compliance with current EMC regulations securely.
• Securely tighten the cable connections using an appropriate open-ended
spanner.
• Measure the output levels of the other cassettes and tune them to a uniform
output level using the appropriate level controls or software dependent on
the head-end station used. Please regard the assembly instructions of the
respective head-end station.
—> In order to prevent interference within the head-end station and the
cable system, the output level of the cassette must be lowered by
4 dB compared to the analogous level (PAL).
• Mount the front cover (see assembly instructions of the head-end station).