background image

 

IPTV EPG-Server

 

EN 

4

 

 

Install the unit in a dry location without infiltration or condensation of water. In case of the formation of 
condensation wait until the system is completely dried. 

 

Do not expose it to dripping or splashing. 

 

If any liquid should accidentally fall into the cabinet, disconnect the power plug. 

 

Install the head-end station where it is protected from direct exposure to sunlight 

 

Install the head-end station not within the immediate vicinity of heat sources 

 

Do not install the head end in cabinets or recesses which are not ventilated. 

 

Do not place any vessels containing liquids on the head-end station. 

 

Do not place anything on the head-end station which could initiate fires. 

 

 

To avoid any risk of overheating

 

 

Install the unit in a well aired location and keep a minimum distance around the apparatus for sufficient 
ventilation 

 

Do not place anything on the unit that might cover the ventilation holes. 

 

Do not install the product in a dusty place  

 

Use the apparatus only in moderate climates (not in tropical climates) 

 

Respect the minimum and maximum temperature specifications 

 

Ensure that the headend station is adequately ventilated. 

 

 

To avoid any risk of electrical shocks

 

 

Controller must be correctly grounded according to applicable national regulations.  

 

For a complete disconnection from the mains, the mains plug must be pulled out of the mains socket. Ensure 
that the mains plug can be pulled out without difficulties. 

 

Pull out power plug when making connections of cables.  

 

To avoid electrical shock, do not open the housing. 

 

 

To avoid interferences with LTE services in Europe

 

 

Do not select a channel higher than UHF 48 in countries with LTE II / 700 operation 

 

Do not select a channel higher than UHF 60 in countries with LTE I / 800 operation 

 

Use coaxial cables with screening effectiveness of >85dB (Class A) at least or >95dB (Class A+) 

 

 

WEEE disposal

 

Electronic devices should never be disposed of in the household rubbish. In accordance with directive 
2002/96/EC of the European Parliament and the European Council from January 27, 2003 which 
addresses old electronic and electrical devices, such devices must be disposed of at a designated 
collection facility. At the end of its service life, please take your device to one of these public collection 
facilities for proper disposal. 

 

 

 

Содержание 492095

Страница 1: ...User Manual IPTV EPG Server Article Article no IPTV EPG Server 492095 Version V1 1 Date 2021 11 EN...

Страница 2: ...ecting to the EPG Server 8 5 2 TDX Setup 8 5 3 STATUS 9 5 4 SETTINGS 10 5 4 1 Device Settings 10 5 4 2 Server Settings 10 5 4 3 How to change from SINC to REACH XML format 11 5 5 SECURITY 12 5 6 SOFTW...

Страница 3: ...etic compatibility make sure all connections are tight and that the covers are screwed on securely Take action to prevent static discharge when working on the device Due to the risk of fires caused by...

Страница 4: ...minimum and maximum temperature specifications Ensure that the headend station is adequately ventilated To avoid any risk of electrical shocks Controller must be correctly grounded according to applic...

Страница 5: ...es Middleware Solutions for Hotel IPTV systems with an eXtensive Markup Language XML file with the EPG data normally contained in a DVB Transport Stream Barker Channel from satellite cable and terrest...

Страница 6: ...k size TB 2 Maximum supported file size GB 4 Maximum supported filename length 255 characters General Data I O connector IP Stream RJ45 Ethernet Input connector USB AUX USB female Input connector DC D...

Страница 7: ...IPTV EPG Server 7 EN 4 Mounting the IPTV EPG Server 4 1 Installing the device The IPTV EPG Server can be mounted in a 19 rack or wall mounted in any direction needed 4 2 Device overview...

Страница 8: ...ave access to the same IP Subnet as the Server 5 2 TDX Setup Before getting started make sure the headend is setup with a unique TSID and ONID and each channel has a unique SID Setup the headend to de...

Страница 9: ...Events fields These show how many services the server is currently receiving data for through the Barker channel This number may differ from the number of services reported by the TDX since not all s...

Страница 10: ...4 2 Server Settings Enter the Barker channel IP you entered when setting up the TDX here You should now be able to access the EPG data in the selected XML format from your middleware solution Note To...

Страница 11: ...tsReach and click the Apply button It should be applied right away and no need to restart Changes at the EPG Transfer Service GUI When changing the Samsung API Path at the EPG Servers GUI it is needed...

Страница 12: ...e the manual for the TRIAX EPG Transfer Service 5 5 SECURITY In this menu you can change the password for the EPG Server as well as the time that must pass for an auto logoff if wanted Default session...

Страница 13: ...d in section above is not working then it is possible to upgrade through a USB key This is the same way if using a recovery image if the device is bricked or not accessible through the GUI Remember to...

Страница 14: ...G Server is to translate the data provided by the TDX via the Barker channel to the supported XML file formats The Barker channel itself does not contain the service names but provides EPG data for ea...

Страница 15: ...nstrates how the XMLTVFormat may be presented after a timezone correction and after the DVB Triplets have been translated into the actual service names 5 9 Information necessary for the Middleware Ser...

Страница 16: ...bers from the IPTV EPG Server This means that the number 10 is represented as an A the number 11 is represented as a B and the number 15 is represented as an F The SINC server has a special XML format...

Страница 17: ...7 EN 6 Support Support information in your language will be found on our country sites Go to www triax com and select your country Below the Support Training menu you will find additional help and sup...

Страница 18: ...in NIT According to standard ETSI EN 300 468 ONID Original Network Identification used in NIT According to standard ETSI EN 300 468 STB Set Top Box DVB receiver that is connected to a TV set Receiver...

Отзывы: