background image

IPTV EPG-Server 

 

 

EN

 

1

 

Safety regulations and notes 

 

ATTENTION 

 

Failure to comply with the specified precautionary measures may cause serious injury to persons or damage 
to property. 

 

The assembly, installation, additional electrical wiring, servicing installation and commissioning may only be 
performed by suitably qualified persons, technicians or installers in compliance with safety regulations. 

 

Damage due to improper installation and commissioning, defective connectors on cables or any other 
incorrect handling will void the warranty. 

 

CAUTION 

 

The devices meet the EU directives 

2011/65/EU, 2014/30/EU and 2014/35/EU

.  

 

The safety requirements are according to the standards EN/DIN EN 50083 resp. IEC/EN/DIN EN 60728 and 
must be observed, especially concerning equipotential bonding and earthing. 

 

Observe the relevant country-specific standards, regulations and guidelines on the installation and operation 
of antenna systems. 

 

Before starting installation or service work disconnect the receiving system from mains. 

 

Installation or service work should NEVER be undertaken during electrical / thunderstorms. 

 

Avoid short circuits! 

 

To ensure electromagnetic compatibility, make sure all connections are tight and that the covers are screwed 
on securely. 

 

Take action to prevent static discharge when working on the device!  

 

Due to the risk of fires caused by lightning strikes, we recommend that all mechanical parts (e.g. distributor, 
equipotential bonding rail, etc.) be mounted on a non-combustible base. Wood panelling, wooden beams, 
plastic covered panels and plastic panels are all examples of combustible bases. 

 

 

Back up battery:

 

The unit includes a preinstalled Lithium battery (CR2032) as backup power source for the clock. 

Type: Varta 

6032101501, 

Battery,

 Coin Cell, Single Cell, 3 V, 2032, 230 mAh 

Do not attempt to replace the non-rechargeable coin-cell battery. Replacement of the battery must only be done 
by a special trained technician. 

There is a danger of an explosion if the coin-cell battery is incorrectly placed. The lithium battery contains 
lithium and can explode if it is not properly handled, or disposed of. Replace only with a battery of the same 
type. To avoid possible injury or death, do not: (1) Throw or immerse into water, (2) allow it to heat more than 
100°C (212°F) or (3) attempt to repair of disassemble it. Dispose of it as required by local ordinance or 

regulations and your company’s safety standards

 

 

To prevent fire, short circuit or shock hazard

 

 

Do not expose the unit to rain or moisture. 

Содержание 492095

Страница 1: ...User Manual IPTV EPG Server Article Article no IPTV EPG Server 492095 Version V1 1 Date 2021 11 EN...

Страница 2: ...ecting to the EPG Server 8 5 2 TDX Setup 8 5 3 STATUS 9 5 4 SETTINGS 10 5 4 1 Device Settings 10 5 4 2 Server Settings 10 5 4 3 How to change from SINC to REACH XML format 11 5 5 SECURITY 12 5 6 SOFTW...

Страница 3: ...etic compatibility make sure all connections are tight and that the covers are screwed on securely Take action to prevent static discharge when working on the device Due to the risk of fires caused by...

Страница 4: ...minimum and maximum temperature specifications Ensure that the headend station is adequately ventilated To avoid any risk of electrical shocks Controller must be correctly grounded according to applic...

Страница 5: ...es Middleware Solutions for Hotel IPTV systems with an eXtensive Markup Language XML file with the EPG data normally contained in a DVB Transport Stream Barker Channel from satellite cable and terrest...

Страница 6: ...k size TB 2 Maximum supported file size GB 4 Maximum supported filename length 255 characters General Data I O connector IP Stream RJ45 Ethernet Input connector USB AUX USB female Input connector DC D...

Страница 7: ...IPTV EPG Server 7 EN 4 Mounting the IPTV EPG Server 4 1 Installing the device The IPTV EPG Server can be mounted in a 19 rack or wall mounted in any direction needed 4 2 Device overview...

Страница 8: ...ave access to the same IP Subnet as the Server 5 2 TDX Setup Before getting started make sure the headend is setup with a unique TSID and ONID and each channel has a unique SID Setup the headend to de...

Страница 9: ...Events fields These show how many services the server is currently receiving data for through the Barker channel This number may differ from the number of services reported by the TDX since not all s...

Страница 10: ...4 2 Server Settings Enter the Barker channel IP you entered when setting up the TDX here You should now be able to access the EPG data in the selected XML format from your middleware solution Note To...

Страница 11: ...tsReach and click the Apply button It should be applied right away and no need to restart Changes at the EPG Transfer Service GUI When changing the Samsung API Path at the EPG Servers GUI it is needed...

Страница 12: ...e the manual for the TRIAX EPG Transfer Service 5 5 SECURITY In this menu you can change the password for the EPG Server as well as the time that must pass for an auto logoff if wanted Default session...

Страница 13: ...d in section above is not working then it is possible to upgrade through a USB key This is the same way if using a recovery image if the device is bricked or not accessible through the GUI Remember to...

Страница 14: ...G Server is to translate the data provided by the TDX via the Barker channel to the supported XML file formats The Barker channel itself does not contain the service names but provides EPG data for ea...

Страница 15: ...nstrates how the XMLTVFormat may be presented after a timezone correction and after the DVB Triplets have been translated into the actual service names 5 9 Information necessary for the Middleware Ser...

Страница 16: ...bers from the IPTV EPG Server This means that the number 10 is represented as an A the number 11 is represented as a B and the number 15 is represented as an F The SINC server has a special XML format...

Страница 17: ...7 EN 6 Support Support information in your language will be found on our country sites Go to www triax com and select your country Below the Support Training menu you will find additional help and sup...

Страница 18: ...in NIT According to standard ETSI EN 300 468 ONID Original Network Identification used in NIT According to standard ETSI EN 300 468 STB Set Top Box DVB receiver that is connected to a TV set Receiver...

Отзывы: