Alarm mode

Display response

Audible

Screen color and action icon change to red, 360° Safety Halo flashes red, audible alarm sounds

Mute

Screen color and action icon change to red, 360° Safety Halo flashes red, audible alarm is mute

Night

Screen color and action icon stay the same brightness, 360° Safety Halo dims if enabled in the Safety Halo setup, 

audible alarm is mute

Note: 

The display responses for night mode occur during the timeframe specified in the night mode settings.

Table 9: Alarm modes

Setting the audible alarm delay

Set up a delay for the audible alarm to reduce nuisance alarms when you open the door. With the audible alarm delay, the screen and 

the 360° Safety Halo flash red but the alarm does not sound for the period of time that you set.

1.  On the home screen, tap the 

User Menu

 icon. 

2.  On the user menu screen, tap 

Alarm

.

3.  On the alarm screen, tap the 

Audible Alarm Delay

 arrow.

4.  To adjust the alarm delay period up to 60 seconds, move the slider. 

5. 

To confirm the new settings, tap the 

Checkmark

 icon.

Changing the audible alarm snooze

The audible alarm snooze temporarily mutes the alarm by the duration you specify. To snooze the audible alarm, tap anywhere on the 

home screen. While the alarm is in snooze, a timer displays over the alarm icon counting down until the alarm sounds again.

1.  On the home screen, tap the 

User Menu

 icon. 

2.  On the user menu screen, tap 

Alarm

.

3.  On the alarm screen, tap the 

Audible Alarm Snooze 

arrow and use the slider to change the snooze time to up to 60 minutes. 

Switching on and adjusting the brightness of the 360° Safety Halo

1.  On the home screen, tap the 

User Menu

 icon. 

2.  To adjust settings for the 360° Safety Halo, tap the 

Safety Halo Setup 

arrow.

3.  To turn the 360° Safety Halo on, switch 

Enabled

 on.

4.  To adjust the brightness, move the slider to increase or decrease 

Brightness

.

5. 

To confirm the new settings, tap the 

Checkmark 

icon.

Adjusting the 360° Safety Halo nightly auto-dim and dimmed period

Change the nightly auto-dim feature to reduce the brightness of the 360° Safety Halo to a specified percentage and determine the time 

period in which you want to dim the light of the 360° Safety Halo.

1.  On the home screen, tap 

User Menu

 icon. 

2.  To view the nightly auto-dim feature for the 360° Safety Halo, tap 

Safety Halo Setup

.

3.  Switch on nightly auto-dim and move the slider to increase or decrease the 

Dimmed Level

.

4.  To adjust the period of time in which you want to dim the light of the 360° Safety Halo, tap 

Dimmed Period

 and scroll to the 

preferred start and end time.

5. 

To confirm the new settings, tap the 

Checkmark 

icon.

Setting the night mode

You can mute the audible alarm during the night. The screen and 360° Safety Halo still flash red when the monitor goes into alarm 

mode.

1.  On the home screen, tap the 

User Menu

 icon. 

2.  On the user menu screen, tap 

Alarm

.

3.  On the alarm screen, the 

Night Mode

 arrow.

4.  To set up a time period for the night mode, scroll to the preferred time under 

Start Time

 and 

End Time

.

5. 

To confirm your settings, tap the 

Checkmark

 icon.

Adjusting the alarm mode

When the differential pressure goes out of range, the display goes into alarm state. When you adjust the alarm mode, you can control 

how the display responds. See 

Table 9

 

for more information.

1.  On the home screen, tap the 

User Menu

 icon. 

2.  On the user menu screen, tap 

Alarm

.

3.  On the alarm screen, expand 

Alarm Mode

 and choose from the following options:

• 

Audible

• 

Mute

• 

Night

4. 

To confirm your settings, tap the 

Checkmark

 icon.

Содержание FMS-2000M

Страница 1: ...1 FMS 2000M Critical Environment Monitor LIT 12013580 November 2020 User s Guide ...

Страница 2: ...voltage wiring and equipment Failure to isolate network wiring and network devices from high voltage wiring and equipment can result in damage to network devices or poor network performance Risk of Property Damage Label all wires prior to disconnecting the equipment Failure to label the wires may cause improper equipment operation after reconnecting the equipment Risk of Property Damage Do not con...

Страница 3: ...he FMS 2000M Critical Environment Monitor IMPORTANT Maintain proper polarity and voltage or current ratings Improper polarity or exceeding the voltage or current ratings will void the warranty IMPORTANT Do not install the FMS 2000M Critical Environment Monitor where the maximum temperature exceeds 125 F 52 C Installing the device where maximum temperatures exceed 125 F 52 C may cause damage to the...

Страница 4: ...ériels Ne passez pas les câbles de communication réseau dans les mêmes gaines chemins de câbles ou panneaux que les câbles à haute tension supérieure à 30 Vca Isolez tous les câbles et appareils réseau des câbles et appareils à haute tension Un défaut d isolement des câbles et appareils à haute tension peut provoquer des dommages aux appareils réseau et réduire les performances du réseau Risque de...

Страница 5: ...rant Une mauvaise polarité ou le dépassement de la tension ou du courant annulera la garantie IMPORTANT N installez pas le contrôleur d environnement critique FMS 2000M où la température maximum dépasse 52 C 125 F Installer l appareil dans un environnement où la température maximum dépasse 52 C 125 F peut endommager FMS 2000M Critical Environment Monitor et peut annuler la garantie IMPORTANT N uti...

Страница 6: ... access level of a restricted user to an admin user 16 Changing the access level of an admin user to a restricted user 16 Updating the PIN of a restricted user 16 Forgetting your password or PIN 16 Network setup 17 BACnet MS TP network setup 17 Setting up the device ID offset 17 Setting up the MaxMaster 17 Choosing the baud rate 17 Setting the MAC address for BACnet MS TP 17 Room setup 18 Naming t...

Страница 7: ...rightness 24 Changing the isolation mode 24 Quick links 24 Adjusting the 360 Safety Halo and brightness 24 Adjusting the alarm mode quick links 24 Adjusting the isolation mode quick link 24 Upgrading an FMS 1655M monitor to an FMS 2000M monitor 25 Technical specifications 26 Cleaning the display 27 North American Emissions Compliance 28 ...

Страница 8: ...d the 360 Safety Halo illuminated edge means that staff can easily monitor spaces down long corridors You can mute the audible alarm with one tap to the screen to reduce audible alarm fatigue The FMS 2000M features two password protected access levels one for administrators and one for restricted level users such as nurses Number Description 1 User menu 2 Room name or parameter name 3 Parameter st...

Страница 9: ...ode Home screen Revert Information Table 2 Icon overview Icon Sensor readings Switch is off Switch is on Next Expand menu Collapse menu Checkmark to confirm Delete or cancel More options Figure 2 Warning screen Figure 3 Alarm screen Figure 4 Neutral isolation mode The icons the screen color and the color of the 360 Safety Halo change with the alarm status or neutral isolation mode ...

Страница 10: ...the monitor In Figure 5 the device monitors two rooms For the second room two network variables display below the pressure reading In Figure 6 the device monitors three rooms For the first and second room one network variable displays below the pressure reading In Figure 7 the device monitors four rooms For the first three rooms one network variable displays below the pressure reading For informat...

Страница 11: ... the network variable that displays on the home screen 1 On the home screen tap the arrow next to the network variable If no arrow is visible no other network variables are available 2 A pop up menu appears that displays the readings for each variable at once as shown in Figure 9 3 On the home screen tap the variable that you want to appear If you monitor two rooms you can select two variables to ...

Страница 12: ...ure 10 FMS 2000M system diagram Item Component 1 FMS 2000M monitor 2 Remote pressure sensor 3 BMS 4 Temperature sensor 5 Humidity sensor 6 Air flow sensor 7 Air changes 8 CO2 sensor System overview Table 3 FMS 2000M system diagram ...

Страница 13: ...landscape orientation in the initial setup in step four The first screen that appears in the inital setup is the Language screen 1 On the Language screen scroll to your preferred language and tap the Checkmark icon 2 On the Global screen expand Units and tap to select whether values display as Imperial or Metric 3 Expand Device Orientation and tap to select Portrait or Landscape screen orientation...

Страница 14: ...he Settings menu 2 To view global settings tap Global 3 To adjust settings for the 360 Safety Halo tap the Safety Halo arrow 4 To turn the 360 Safety Halo on switch on Enabled 5 To view the brightness adjustment slider tap the Plus icon 6 To adjust the brightness move the slider to increase or decrease the brightness 7 To confirm the new settings tap the Checkmark icon Adjusting the 360 Safety Hal...

Страница 15: ...a PIN password for a restricted user use the following criteria Zero to nine numeric Four to eight digits in length Creating the admin user account and password The first user must be an admin You cannot set up a restricted user until you set up an admin Admin level users have access to the entire device 1 On the home screen tap the Settings icon to enter the Settings menu 2 To view all user accou...

Страница 16: ...assword twice 6 To confirm the change tap the Checkmark icon Changing the access level of an admin user to a restricted user 1 On the home screen tap the Settings icon to enter the Settings menu 2 To view all user accounts information tap User Accounts 3 To change the access level of an admin user tap Edit 4 On the Edit User screen tap Administrator and select Restricted 5 Tap Create PIN and enter...

Страница 17: ...iciency 1 On the home screen tap the Settings icon to enter the Settings menu 2 To view network settings tap Network 3 To view the MaxMaster tap BACnet Protocol 4 To adjust the MaxMaster move the slider towards the Plus icon to increase or the Minus icon to decrease the parameter You can also tap the Plus or Minus icon to make adjustments 5 Optional Tap the Revert icon to revert to the previous se...

Страница 18: ...tive Only Negative Only Positive and Negative 4 To save the new settings collapse Isolation Mode Configuring the door switch If you install a door switch you can enable the door switch adjust the switch type and adjust the alarm delay The door switch reduces false positive alarms each time the door opens Instead the audible alarm is silent and a yellow warning screen appears and the 360 Safety Hal...

Страница 19: ...arm setpoint 1 Yes Yes Yes Yes AV 3 Differential Pressure low warning setpoint 1 Yes Yes Yes Yes AV 4 Differential Pressure high warning setpoint 1 Yes Yes Yes Yes AV 5 Differential Pressure high alarm setpoint 1 Yes Yes Yes Yes AV 6 Network Variable Humidity 1 Yes Yes Yes Yes AV 7 Network Variable Temperature 2 No Yes Yes Yes AV 8 Differential Pressure low alarm setpoint 2 No Yes Yes Yes AV 9 Dif...

Страница 20: ...o Yes Objects Analog values Read Write Availability of analog value objects FMS2M Bx1x FMS2M Bx2x FMS2M Bx3x FMS2M Bx4x AV 25 Network Variable Flow 1 Read or write Yes Yes Yes Yes AV 26 Network Variable Air changes 1 Yes Yes Yes Yes AV 27 Network Variable CO2 1 Yes Yes Yes Yes AV 28 Network Variable Flow 2 No Yes Yes Yes AV 29 Network Variable Air changes 2 No Yes Yes Yes AV 30 Network Variable CO...

Страница 21: ...O 4 On the analog screen tap the Zero Calibration arrow 5 On the zero callibration screen tap the Create Zero Offset arrow 6 Follow the instructions on screen and wait for the real time view reading on the screen to stabilize for at least 10 seconds 7 To create a zero offset tap Proceed Resetting the zero offset If creating a zero offset does not result in a zero differential pressure reading when...

Страница 22: ... Settings icon 2 On the settings screen tap Diagnostics 3 On the diagnostics screen tap the About this FMS arrow Rebooting the monitor 1 On the home screen tap the Settings icon 2 On the settings screen tap Diagnostics 3 On the diagnostics screen tap Reboot Monitor 4 Tap Proceed to perform a soft reboot Restricted user access Restricted level users have access to the user menu and the quick links ...

Страница 23: ... icon 2 To adjust settings for the 360 Safety Halo tap the Safety Halo Setup arrow 3 To turn the 360 Safety Halo on switch Enabled on 4 To adjust the brightness move the slider to increase or decrease Brightness 5 To confirm the new settings tap the Checkmark icon Adjusting the 360 Safety Halo nightly auto dim and dimmed period Change the nightly auto dim feature to reduce the brightness of the 36...

Страница 24: ...on the Home screen 3 On the user menu screen tap Isolation Mode 4 Tap one of the available isolation modes 5 To confim the the isolation mode settings tap the Checkmark icon Use the quick link icons on the home screen to quickly access the isolation mode 360 Safety Halo and alarm mode Adjusting the 360 Safety Halo and brightness 1 On the home screen tap the Halo icon 2 On the Safety Halo screen sw...

Страница 25: ...MS 2000M display If you use a BACnet network connect the networking cable to the 3 pin header See Figure 11 8 To complete the installation refer to the FMS 2000M Critical Environment Monitor Installation Guide LIT 12013555 Upgrading an FMS 1655M monitor to an FMS 2000M monitor Callout Description 1 FMS 2000M monitor 2 FMS 1655M remote sensor 3 Red display power wire If the sensor includes a 3 posi...

Страница 26: ...ction Up to 50 user passwords with 2 access levels administrator and restricted Communications protocol BACnet MS TP to BAS 76 8k 38 4k 19 2k 9600 baud Power requirement 24 VAC nominal 21 6 VAC minimum 26 4 VAC maximum 50 60 Hz 30 VA power supply Class 2 Limited Energy or LPS isolated power supply Power consumption 30 VA maximum Optional input power supply Universal 120 VAC 240 VAC to 24 VAC 30 VA...

Страница 27: ... or isopropyl alchohol or kerosene IMPORTANT N appliquez pas de nettoyant directement sur la surface du panneau tactile Si du nettoyant pénètre dans le panneau tactile essuyez immédiatement le nettoyant à l aide d un chiffon absorbant N utilisez aucun nettoyant qui est acide ou alcalin Utilisez un nettoyant dont le pH est neutre N utilisez pas de produits chimiques organiques comme le diluant pour...