background image

9/11/09

2007-37 Prestige Wall Frame Instructions

Wall Frame Mounting Guidelines

1. The wall frame is designed for stud spacing of

12”  or  16”  on  centers.  The  wall  mounting
brackets on the frame are adjustable to accom-
modate most unconventional stud spacing.

2. For  applications  using  wood  studs,  install  the

wall frame using the lag screws provided with
the  boiler.  Ensure  all  4  lag  screws  are  utilized
and are installed securely in the studs.

3. For  applications  using  metal  studs,  install  the

wall frame to the studs using 3/16” toggle bolts
and washers.

4. DO  NOT  mount  or  attempt  to  mount  the  wall

frame to hollow sheet rock or lath walls using
anchors. Only install the wall frame to studs or
equivalent wood structure.

Wall Frame Mounting

1. Locate the wall studs in the general boiler loca-

tion.

2. Position  the  Wall  Frame Assembly  against  the

wall.    Level  the  assembly  and  mark  the  wall
where the slots of the Wall Mounting Brackets
align with the wall studs.

3. Remove  the  Wall  Frame  Assembly  from  the

wall.    For  applications  using  wood  studs,  drill
1/4” diameter by 3” deep holes at the center of
each mark.  For applications using metal studs
and  3/16”  toggle  bolts,  drill  the  required  size
holes.

4. Reposition  the  Wall  Frame Assembly  onto  the

wall and align the mounting bracket slots with
the  wall  holes.    Secure  the  Wall  Frame
Assembly to the wall using the lag bolts provid-
ed with the boiler for wood studs or toggle bolts
for metal studs.

5. Locate  the  boiler  mounting  bracket  supplied

with  the  boiler.    Level  and  center  the  boiler
mounting bracket on the Wall Frame Assembly
and  install  using  the  bolts  provided  in  this  kit.
Ensure  that  the  upper  edge  of  the  bracket  is
away from the Wall Frame Assembly.

Boiler Mounting

1. Ensure that all Wall Frame Assembly bolts are

tight and that the Assembly is firmly attached to
the wall before mounting the boiler.

Use  extreme  care  not  to  drop  the  boiler  or
cause bodily injury while lifting or mounting
the  boiler.    Once  mounted,  verify  that  the
boiler  is  securely  attached  to  the  bracket.
Failure  to  comply  with  the  above  guidelines
could  result  in  property  damage,  personal
injury or death.

2.   The boiler is too heavy and bulky for a single

person to lift and mount; a minimum of 2 peo-
ple are required for mounting the boiler.

3. Install the boiler making sure the boiler mount-

ing lip located along the upper edge of the rear
jacket  engages  the  boiler  mounting  bracket.
Ensure  the  boiler  is  seated  properly  and  is
secure. 