DHW OPERATING SIGNAL SELECTION
(PARAMETER 46)
The type of domestic call signal can be changed with
Parameter 46. Parameter 46 allows the selection of
either an Aquastat or NTC Sensor as the signaling
device for a domestic call.
DHW Operating Signal Selection Options
(Parameter 46)
Prestige Excellence with NTC Sensor – Factory
Setting (Parameter 46 = 02)
The domestic call is initiated from an NTC sensor in the
Indirect Water Heater. The setpoint for domestic hot
water in the Indirect Water Heater is set with Parameter
1. The domestic water temperature is monitored and
compared to the domestic hot water setpoint to deter-
mine if a domestic call is needed. The domestic water
temperature can be monitored on the boiler display via
item 3 of the INFO menu.
Prestige Solo with NTC Sensor
(Parameter 46 = 12)
The domestic call is initiated from an NTC sensor in the
Indirect Water Heater. The setpoint for domestic hot
water in the Indirect Water Heater is set with Parameter
1. The domestic water temperature is monitored and
compared to the domestic hot water setpoint to deter-
mine if a domestic call is needed. The domestic water
temperature can be monitored on the boiler display via
item 3 of the INFO menu.
Prestige Solo with Aquastat – Factory Setting
(Parameter 46 = 13)
The domestic call is initiated from an aquastat in the
Indirect Water Heater. The presence of a domestic call
can be displayed on the boiler via item 3 of the INFO
menu. A reading of
-22
indicates no domestic call is
present. A reading of
230
indicates a domestic call is
present.
Parameter 46 Adjustment
To change Parameter 46, requires entering the Access
Code as outlined on page 2. After entering the Access
Code, press the MODE button until the display shows
PARA
. Press the STEP button to reach Parameter 46.
Press the “+” or “–“ button to change the setting of
Parameter 46 to the desired setting. Press the STORE
button and confirm that the display blinks to indicate the
setting has been stored.
Parameter 46 has multiple settings available in addi-
tion to the settings listed. DO NOT set Parameter 46
to any setting other than those listed above. Failure
to comply can result in erratic or unreliable opera-
tion of the Prestige Boiler.