![TriangleTube Delta Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/triangletube/delta/delta_installation-and-maintenance-manual_1160052018.webp)
12
Domestic Piping
7
8
1
10
To dishwasher if
permitted by codes
2
3
U-Tube
assembly
Optional Recirculation Line
3
Optional
12" Heat trap
Cold water
inlet
4
3
3
6
9
Fig. 3: MODULATING DELTA
With Recirculation
1. Mixing valve with check valve
2. Flow check valve
3. Shut off valve
4. Backflow preventer or pressure reducing valve*
6. Thermal expansion tank*
7. Circulator (controlled by aquastat)
8. Domestic drain valve
9. Vacuum breaker*
10. Recirculation Aquastat
Note:
All shut off valves
shown in this figure must be
closed when siphon draining
the MODULATING DELTA
* Optional devices may be required by local codes or installation requirements
Optional
12" Heat trap
8
1
To dishwasher if
permitted by codes
3*
Cold water
inlet
4
3
3
6
9
U
assembly
7
2
3
Optional Recirculation Line
10
Fig. 4: Multiple MODULATING DELTAS Installation With Recirculation