9
Model 300 MICROFACER™
92-0756 : Rev. 060811
INSTALLATION
Slide the tube to be worked on into the saddle, leaving approximately 1/8” (3 mm)
between the tool bit and the end of the tube.
INSERT IMAGE
Tighten the saddle set by turning the clamp knob below the saddle set.
MACHINING SEQUENCE
Turn the motor on and let it slowly rotate to ensure that the tool bit does not make
contact with the end of the tube at this time.
Loosen the clamp knob to release the saddle set and remove the machined tube.
Clamp Knob
Set Screws
(Retaining
Tool Bit)
Feed Knob