Page 24
The primary purpose of the Maintenance and Troubleshooting section of this manual is
to permit the user to perform required preventive maintenance, perform minor
adjustments and to correct minor malfunctions caused by incorrect/unacceptable
contacts.
Detailed instructions for adjusting and changing indenters are also given. In the event
it is necessary to replace an item which has become defective and for which there is
no specific disassembly instructions, use extreme care and/or consult the factory for
assistance.
The only preventive maintenance required for the TAC is the periodic inspection and
replacement of air filter F-1 and vacuum filter RFV-1. See Figure 6-2. Whenever it is
observed that filter F1 has accumulated moisture on the bottom, the moisture should
be drained by placing a cup or other container under F1, opening the sleeve valve,
opening the F1 drain, and draining the filter.
Do not allow the moisture to spray, drip or enter the cabinet when draining.
The vacuum filter RFV-1 can easily be located in-line between the transfer tip holder
and the TAC Control Unit. If the vacuum filter becomes clogged, decreased
performance with part detection at the transfer tip will be observed. When this situation
occurs, replacement of the vacuum filter is suggested. Please note the vacuum filter
orientation when removing, as the replacement filter must be installed with the same
orientation.
A vacuum circuit purge is also suggested any time a degraded performance of part
detection occurs. This can be done by performing the following steps: (Refer to Figure
6-1and 6-2).
Step 1.
Turn off air supply.
Step 2.
Unplug Power cord from wall outlet.
Step 3.
Remove the transfer tip from the tip holder.
Step 4.
Remove control unit cover plate.
Step 5.
Turn on air supply
Step 6.
Plug exhaust port of vacuum generator (VG-1) with finger for
approximately 10 seconds.
Step 7.
Repeat step 6 several times.
Step 8.
Turn off air supply.
Step 9.
Replace transfer tip to tip holder.
Step 10.
Replace control unit cover plate.
Step 11.
Plug power cord to wall outlet.
Step 12.
Turn on air supply at sleeve valve.
I
NTRODUCTION
M
AINTENANCE
&
TROUBLESHOOTING
Section 6
Содержание TAC 17X
Страница 5: ...Page 5 Figure 1 1 TAC 17X Front View ...
Страница 7: ...Page 7 Figure 1 2 Wire Insertion Through Funnel ...
Страница 10: ...Page 10 Primary air input at rear of TAC Figure 2 1 Pneumatic Hook Ups ...
Страница 16: ...Page 16 Crimp Inspection Points Improper Crimps Figure 3 3 Crimped Samples ...
Страница 25: ...Page 25 Figure 6 1 TAC 17X Pneumatic Control Panel ...
Страница 26: ...Page 26 Figure 6 2 TAC 17X Components Right View ...
Страница 38: ...Page 38 ...
Страница 39: ...Page 39 Carefully Remove Hose Clamp ...
Страница 42: ...Page 42 ...
Страница 47: ...Page 47 Figure 7 3 TAC 17X Pneumatic Diagram ...