background image

 

INSTALLING THE POOL HEATER 

 
Pool Heater installation is divided into two sections: 

electrical connections, and pool piping

 

connections.

 The Factory has fully installed the refrigeration loop and preset the controls. There are 

no job-site installation requirements for the heat pump. 

Wiring should only be done by licensed 

electricians. 

 
 

ELECTRICAL CONNECTIONS

 

Power to the Pool Heater 
 

The AQUEFIER Pool Heater requires a separate 230 volt, 50 amp. circuit with a breaker, and a 
ground connection. The pool heater grounding conductor shall be the same size or larger than the 
live power supply conductors. 
 
Use a length of watertight flexible conduit to connect to the Pool Heater cabinet. Enter the Pool 
Heater cabinet through the openings provided at the rear corner of the cabinet. Connect to the pigtail 
provided inside the cabinet or wire direct to the heat pump control box. Ground the heat pump per 
local codes. 
 
This pool heater is to be installed in accordance with Article 680 of the National Electrical Code, 
ANSI/NFPA 70, and with the requirements of the authority having jurisdiction.   
 
For more detailed instructions on installing the power refer to the Goodman Heat Pump instructions 
enclosed. 
 

Bonding to Pool Steel:

 Electrical corrosion, known as electrolysis, will occur if the heater is not 

bonded to the pool reinforcement steel. Most local codes also require that the water pump be 
bonded. Connect using a #8 gauge or larger solid copper wire to bond the cabinet to the pool 
reinforcement steel. 
 

Power to the Pool Pump 

 
A standard feature on the Aquifier Pool Heater is the 

Pump Hold Relay

. Since 

the pool heater can

 

not run without water flow

, the 

Pump Hold Relay

 will keep the pool pump and the pool heater 

running until the pool has reached the desired temperature setpoint. If the pump hold relay is not 
wired in, the heater can only run when the pump is either turned on manually, or by the pump timer. 
 
To wire this important feature in, the pool heater requires a circuit from the pool pump timer to the 
pool heater, and a circuit from the pool heater to the pool pump. See Figure 1, Pool Pump to Hold 
Relay Wiring Schematic. The Pump Hold Relay can be used with either a 120 volt or a 230 volt, 1 
phase pump, with current draws up to 25 amps. It should be noted that power to the pump can be 
supplied by the Timer and the Pump Hold Relay at the same time. The polarity of both sources of 
power to the pump must be the same. See Figure 1.  The power supply to the timer and the pump 
hold relay must come from the same breaker. 

Содержание WCC100B

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS FOR AQUEFIER POOL HEATER Models WCC100B WCC100C WCC100L Trevor Martin Corp 4151 112th Terrace North Clearwater FL 33762 Bulletin PH 100 0702 ...

Страница 2: ...ture and starts adding heat if required The AQUEFIER Pool Heater will keep your pool pump running until it reaches your chosen temperature even if the pool timer turns off CAUTIONS DISCLAIMERS The AQUEFIER Pool Heater operates in conjunction with your pool equipment Improper installation can cause damage to both your Pool Heater your pool pump and filter piping Only skilled technicians with approp...

Страница 3: ...er temperatures to 100 degrees F c Before entering a pool or tub the user should measure the water temperature at several occupant locations using an accurate thermometer since the tolerance of the water temperature regulating devices may vary as much as or 5 degrees F d Alcohol drugs or medication should not be used before or during pool or tub use since their use may lead to unconsciousness with...

Страница 4: ...by the normal operation of the heat pump 3 Do not install the Pool Heater in an enclosed area such as a filter equipment room It is important to prevent the cool discharge air from being drawn back into the heat pump A beach location presents additional concerns Exposure to salt water spray and high winds will cause premature wear on the heat pump Salt and sand accumulation will clog up the heat p...

Страница 5: ...n Heat Pump instructions enclosed Bonding to Pool Steel Electrical corrosion known as electrolysis will occur if the heater is not bonded to the pool reinforcement steel Most local codes also require that the water pump be bonded Connect using a 8 gauge or larger solid copper wire to bond the cabinet to the pool reinforcement steel Power to the Pool Pump A standard feature on the Aquifier Pool Hea...

Страница 6: ...rect Replace the front panel on the cabinet POOL PIPING CONNECTIONS The Pool Heater is designed to handle the full flow from the pool pump No bypass is required if the water flow is in the 20 to 80 gallon per minute range The Pool Heater piping must be connected at a point in the pool piping loop after the pool water passes through the filter and before the chlorinator or chemical feeder Connectin...

Страница 7: ...b clockwise or counter clockwise or remove the clear plastic weather cover insert the 1 8 th inch hex wrench provided through the opening in the face of the digital temperature control and adjust the set point up or down as desired For more detailed instructions on the digital temperature refer to the Goldline SP 33 instructions enclosed After adjusting the temperature control check the water temp...

Страница 8: ...owed to start for an additional 4 minutes In most cases the heater will not start until at least 8 minutes has passed without resetting the on off switch or the breakers The heater will continue to heat the pool until the temperature setpoint has been satisfied PLEASE NOTE 1 It is important to remember that the pool heater will not run unless the pool pump is running 2 Water vapor will condense on...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ...er Side Pressure Drop Water Flow gal min Pressure Drop psig 20 0 23 30 0 46 40 0 74 50 1 06 60 1 42 70 1 86 80 2 32 Temperature Rise Across Heater Water Flow gal min Temperature Rise deg F 20 10 0 30 6 7 40 5 0 50 4 0 60 3 3 70 2 8 80 2 5 ...

Страница 14: ...s that are installed Check filtering system Check pump and impeller Check that pressure switch is closed needs 2 psi to close Wait at least 8 min without resetting on off switch or breakers Set temperature setpoint above water temperature Goldline control terminals C and NO close on call for heat Pool water does not reach temperature setpoint Heater runs only when pool timer is on Outside air temp...

Страница 15: ... any other liability in connection with this product except as may be authorized by an officer of Trevor Martin Corporation in a signed written document THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT APPLY TO THIS SALE LIMITATION OF REMEDY Trevor Martin Corporation will replace or repair at its option any product or component found to be defective durin...

Страница 16: ......

Отзывы: