10
NOTICE
1.
This unit can evaporate the condensation and distribute through the exhaust hose
automatically.
2.
When the unit is in the cooling function, it does not need the drain pipe installed.
Please make sure that the rubber cap
①
is locked on drain hole, when the unit is
running.
3.
When operating the dehumidifying function the “
①
” rubber cap on drain hose
should be pulled out and install a proper drain hose
②
,please remove the air
exhaust hose, connect a drain hose to the drain hole and lead the water to the
outside in order to intensify dehumidifying capacity.
※
When the water tank is full,"E4" will be displayed on the display panel. Please
remove the rubber cap“
②
” of the drain hole to drain out the water first. After the
drainage is completed, please restart the unit and then the unit can operate
normally.
MAINTENANCE
PLEASE DISCONNECT THE POWER CORD BEFORE
CLEANING.
AIR FILTER
1. The air filter located on both sides of the unit can be
removed simply by pulling the frame out.
2. Wash the filter with cool water (cooler than 40
℃
) every
two weeks, and put filter back after it air-dried naturally.
11
CONDENSER/EVAPORATOR
Use a brush attachment with a vacuum cleaner.
Casing
Wipe with a damp cloth and polish with a soft cloth.
When cleaning the filter, please remove it as the picture.
POWER SUPPLY
(1)
Confirm the correct power.
(2)
Insert the plug into the outlet firmly In order to prevent any dangerous
leakage.
(3)
Don’t pull power wire by force because it will cause damage to power wire.
PLACE FOR USE
(1)
Because the machine distributes hot air, please don’t place or operate in a
narrow place.
(2)
In case of dangerous leak, don’t work the machine in a humid place.
(3)
Don’t place the machine in a sunlit corner otherwise the unit might shut
down due to overheating and the color of the machine may soon fade out.