8
2. The unit will stop humidifying if ambient humidity is equal to the pre-set humidity.
Otherwise it will work as the humidifying procedure1.
3. The fan motor and water motor will work, but compressor doesn’t work.
10.
PURIFICATION
When select this function, the purification indicator light will be on and only the fan
motor works.
When the fan motor’s life time is larger than 2000hrs
,
the indicator light will flash
,
and LCD display E8, it means the filter should be changed
;
Change the filter and
press SPEED button for 3 seconds and alarm reset.
(
This unit’s filter is the
ordinary one, please choose HEPA filter if need.
11. SLEEP CONTROL
FUNCTION
1. While in cooling mode, press the SLEEP key to set the temperature. It
increases1
℃
after an hour and at most increases 2
℃
after 2 hours.
2. Press the SLEEP key again can cancel the setting.
12. SWING
Press this key and the outlet will oscillate and stop when this key is pressed again.
The outlet will close up automatically when the unit stops working.
13. ALARM
When the water tank is full,"E4" will be displayed on the display panel. To resume
operation, please remove the rubber cap of the drain hose to drain out the water
firstly. The E4 warning will disappear after draining, and then you can restart the
unit by pressing the POWER key.
9
REMOTE CONTROL FUNCTION
On/Off switch
Function “MODE” selector
Hourly programming
Automatic fan speed
High fan speed
Low fan speed
Night operation selector
Temperature selector
Swing