TRENDnet TEG-240WS Скачать руководство пользователя страница 26

 

45 

Limited Warranty 

 

TRENDnet warrants its products against defects in material and 

workmanship, under normal use and service, for the following lengths of time 
from the date of purchase.     

 

     

TEG-240WS - 5 Years Warranty 

If a product does not operate as warranted above during the applicable 
warranty period, TRENDnet shall, at its option and expense, repair the 

defective product or deliver to customer an equivalent product to replace the 

defective item.    All products that are replaced will become the property of 
TRENDnet.    Replacement products may be new or reconditioned. 
TRENDnet shall not be responsible for any software, firmware, information, or 
memory data of customer contained in, stored on, or integrated with any 

products returned to TRENDnet pursuant to any warranty. 
There are no user serviceable parts inside the product.    Do not remove or 
attempt to service the product through any unauthorized service center.  
This warranty is voided if (i) the product has been modified or repaired by any 

unauthorized service center, (ii) the product was subject to accident, abuse, 

or improper use (iii) the product was subject to conditions more severe than 
those specified in the manual. 
Warranty service may be obtained by contacting TRENDnet office within the 
applicable warranty period for a Return Material Authorization (RMA) number, 

accompanied by a copy of the dated proof of the purchase.  Products 
returned to TRENDnet must be pre-authorized by TRENDnet with RMA 

number marked on the outside of the package, and sent prepaid, insured and 

packaged appropriately for safe shipment.     
 

WARRANTIES EXCLUSIVE: IF THE TRENDNET PRODUCT DOES NOT 

   

46 

OPERATE AS WARRANTED ABOVE, THE CUSTOMER’S SOLE REMEDY 
SHALL BE, AT TRENDNET’S OPTION, REPAIR OR REPLACEMENT. THE 
FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN 
LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, EITHER IN 
FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, 
INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE. TRENDNET NEITHER ASSUMES NOR 
AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER 
LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, 
MAINTENANCE OR USE OF TRENDNET’S PRODUCTS. 

 

TRENDNET SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS 
TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN 
THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR 
ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER INSTALLATION OR 
TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY, OR ANY 
OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY 
ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD. 

 

LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW 
TRENDNET ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY 
LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING 
NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, 
OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR 
PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATE, OR 
OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH 
THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, 
FAILURE, OR INTERRUPTION OF THE POSSIBILITY OF SUCH DAMAGES, 
AND LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF 
THE PURCHASE PRICE PAID, AT TRENDNET’S OPTION. THIS 
DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF 
ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL 
PURPOSE. 

Governing Law:  This Limited Warranty shall be governed by the laws of the 
state of California. 

Note: AC/DC Power Adapter, Cooling Fan, Cables and Power Supply carry 1-
Year Warranty 

Содержание TEG-240WS

Страница 1: ...quency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to c...

Страница 2: ...ot compromised c Mechanical Loading mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading d Circuit Overloading Consideration...

Страница 3: ...m LEDs 15 1000BASE T Port 1 24 Status LEDs 16 Mini GBIC Port 23 24 Status LEDs 17 Configuration 19 Installing the Web Management Utility 19 Discovery List 20 Monitor List 21 ii Device Setting 23 Toolb...

Страница 4: ...10Mbps Ethernet network capabilities in a highly flexible package Purpose This guide discusses how to install your TEG 240WS 24 Port 10 100 1000Mbps Gigabit Ethernet Web Smart Switch Terms Usage In t...

Страница 5: ...perform 10 times the number of operations in the same amount of time 4 In addition the phenomenal bandwidth delivered by Gigabit Ethernet is the most cost effective method to take advantage of today a...

Страница 6: ...ired make routers relatively impractical Today switches are an ideal solution to most kinds of local area network congestion problems 6 VLAN Virtual Local Area Network A VLAN is a group of end station...

Страница 7: ...Supports IEEE 802 1p Priority Queues Supports Static Port Trunk Supports Jumbo Frame Supports Broadcast Storm Control Supports Port Mirroring Supports Port Setting for Speed Flow control Easy configur...

Страница 8: ...installing consider the following pointers Install the Switch in a fairly cool and dry place See Technical Specifications for the acceptable temperature and humidity operating ranges Install the Switc...

Страница 9: ...Ethernet that runs both in half and full duplex mode and 1000Mbps Gigabit Ethernet runs in full duplex mode using four pairs of Category 5 cable These 1000BASE T ports are Auto MDI type port The Switc...

Страница 10: ...e When the port is set to Forced Mode the Auto MDI MDIX will be disabled 14 Mini GBIC Slots Port 23 24 The Switch is equipped with two combo mini GBIC ports supported optional 1000BASE SX LX mini GBIC...

Страница 11: ...f The CPU is not working 16 1000BASE T Port 1 24 Status LEDs Link ACT Link Activity On When the Link ACT LED lights on the respective port is successfully connected to an Ethernet network Blinking Whe...

Страница 12: ...ansmitting or receiving data on the Gigabit Ethernet network Off Fiber line or mini GBIC module is not installed Speed Green When the Speed LED lights green the respective port is connected to a 1000M...

Страница 13: ...Follow the on screen instructions to install the utility 4 Upon completion go to Program Files web_management_utility and open the Web Management utility Figure 7 20 Figure 7 Web Management Utility Th...

Страница 14: ...e DHCP status of the device z Location Shows where the device is located z Trap IP Shows the IP where the Trap to be sent z Subnet Mask Shows the Subnet Mask set of the device z Gateway Shows the Gate...

Страница 15: ...the password needed in the dialog box and press Set button to proceed the password change immediately Figure 11 Password Change 24 Firmware Upgrade When the device has a new function there will be a n...

Страница 16: ...control and monitor the switch from the local LAN This section indicates how to configure the Switch to enable its smart functions 26 Login Before you configure this device note that when the Web Sma...

Страница 17: ...The Link Status in the screen will show the connection speed and duplex mode else this dialog box will show Down when the port is disconnected Figure 17 Port Setting Note The priority of Gigabit Fiber...

Страница 18: ...ement by allowing users to move devices to a new VLAN without having to change any physical connections The IEEE 802 1Q VLAN Configuration page provides powerful VID management functions The original...

Страница 19: ...g Name and select the ports to be trunked together and click Apply to activate the selected Trunking groups Figure 23 Trunk Configuration Be sure that the selected trunk setting port must connect to t...

Страница 20: ...t and for packets that are untagged the switch will assign the priority in the tag depending on your configuration Figure 25 IEEE 802 1p Default Priority Setting 34 Broadcast Storm Control Setting The...

Страница 21: ...are two ways for the switch to attain IP Static and DHCP Dynamic Host Configuration Protocol When using static mode the IP Address Subnet Mask and Gateway can be manually configured When using DHCP mo...

Страница 22: ...ber Port Event Monitoring the Fiber port status Link Up Link Down a trap when there is linking status happens in mini GBIC connection Twisted Pair Port Event Monitoring the twisted pair port status Li...

Страница 23: ...eset the details displayed 40 To view the statistics of individual ports click one of the Port ID as Figure 33 Figure 33 Port Statistics Factory Reset The Factory Reset helps you to reset the device b...

Страница 24: ...sword will not be erased Firmware Upload The Firmware Upload helps you to backup or upload firmware from to the Switch Once you need to backup the current firmware of the Switch press the Backup butto...

Страница 25: ...4 pair UTP Cat 5 up to 100m Fiber module Mini GBIC Fiber module LC Type Cable Number of Ports 24 10 100 1000Mbps Auto MDIX RJ 45 ports 2 Combo mini GBIC slots Physical and Environmental AC inputs 100...

Страница 26: ...ARRANTED ABOVE THE CUSTOMER S SOLE REMEDY SHALL BE AT TRENDNET S OPTION REPAIR OR REPLACEMENT THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR I...

Страница 27: ...47...

Отзывы: