18
installation
2.2 PMF uniT To STrucTure
2.2.2 installation on steel pile
Figure 11
: Typical installation on steel pile
recoMMended PerSonAl ProTecTiVe
equiPMenT
inForMATion
general PPe
As per site / plant requirements
equiPMenT required
inForMATion
Fasteners
supplied by Trelleborg
While installing on steel pile:
Mounting of the hole locations and connecting plate
sizes of the pile structure must be in accordance to
the approved anchor layout drawing.
recommendations
❙
use the standard bolt torque values when fastening
to the steel.
❙
use torque values from Appendix A when fastening
to fender.