![Trelawny SF11EX Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/trelawny/sf11ex/sf11ex_operation-and-maintenance-manual_1155500012.webp)
PAGE 12
SF11ex DECK hammer
Trouble Shooting
Cause
Action
Machine bounces in use
Air pressure too high.
Ensure that the air pressure is set at 90psi. (6.3bar).
If the air pressure cannot be controlled, close off the SF11Ex on/off
valve slightly until the machine runs smoothly.
Machine performance slow
Worn Cutter Heads
Replace Cutter Heads.
Machine drags on deck or floor
Insufficient air supply
Ensure that the compressor can supply at least 100cfm (free air) at
90psi. The SF11Ex Deck Hammer requires 70cfm
Hose bore too small.
Ensure that the hose bore is 3/4” (19mm).
Hose run too long.
Each 50 ft. (15 metres) of airline used, will drop the pressure by approx-
imately 3 psi.
Worn Pistons and/or cylinders.
Replace piston and cylinders.
If the problem has not been cured by any of the above actions, contact your local dealership or agent for assistance.
Description
Metric
Imperial
Piston diameter
27mm
1.06”
Piston length
89mm
3.50”
Stroke
26.5mm
1.04”
Blows per minute
2300 x 11
Air pressure - (3/4”BSP Air Inlet)
6.2 bar
90psi
Air consumption
33 lps
70cfm
Length (handle lowered)
1300mm
51.2”
Height (Handle raised)
1230mm
48.4”
Work head dimensions
285mm (11.2”)L x 150mm (5.9”)W x 180mm (7.1”)D
Cutting width
252mm
9.9”
Cutting width to edge
15mm
0.59”
Weight
37.2kg
82lbs
Noise level db(A) LpA
103.1
LwA
113.1
Vibration (AEQ) at the Handle Bar*
a=5.8 m/s2 (K= +40% -0%)
technical specification
Noise Levels: Noise level measured in accordance with: EN ISO 15744: 2008
Vibration Levels: Vibration measured in accordance with: EN ISO 28927-9:2012 and EN ISO 20643:2005. (k) Equals the factor of uncertainty, which allows for variations in
measurement and production. Vibration Data figures are tri-axial, which gives the total vibration emission. Because of various factors, the range of vibration from these
tools may vary between -0% +40% (5.8 m/s2 -8.12 m/s2). The vibration is dependent on the task, the operators grip and feed force employed etc.
NOTE: The above vibration levels were obtained from tri-axial measurements to comply with the requirements of “The Control of Vibration at Work Regulations 2005*” and
the revisions to the (8662) now EN ISO 28927-9:2012 and EN ISO 20643:2005 series of standards. These values are at least 1.4 times larger than the values obtained from
single axis measurements. *Based on European Union Council Directive 2002/44/EC (Physical Agents (Vibration) Directive)).
Содержание SF11EX
Страница 1: ...www trelawny co uk www trelawny co uk SF11ex deck hammer operations and maintenance manual...
Страница 10: ...PAGE 10 SF11ex DECK hammer EXPLODED DIAGRAM...
Страница 14: ...PAGE 14 SF11ex DECK hammer notes...
Страница 15: ...www trelawny co uk notes...