5-3 Wiring Interface Connections
WARNING:
The following connection should only be performed by qualified technicians. Damage to equipment will occur if
connections are incorrect.
To interface the wire cutter with the controller, two (2) electrical connections are required.
l
BLUE LEAD – 0 VDC supply
l
BLACK LEAD – 24 VDC supply 0.5 amp.
5-4 Inversing Logic
WARNING:
Before start-up, ensure that all connections are correct or
damage to the wire cutter may occur.
NOTE:
The TOUGH GUN Wire Cutter is factory set for Sourcing
inputs.
1. Remove the exhaust and intake fittings.
2. Place the exhaust fitting in the intake port (see (2) in Figure 5-E).
3. Place the air line fitting in the exhaust port (see (1) in Figure 5-
E).
This change allows the solenoid valve to function as normally open.
In this situation, as the input signal drops to zero voltage, the valve
passage opens, charging the cylinder.
Figure 5-E
OM-WC-1.3