5-2 Installing Wire Cutter to TOUGH GUN® TT3E Reamer
WARNING:
Ensure power supply is off and disconnected before
proceeding. Please follow your facility's lockout/tagout procedures.
A. To Mount Wire Cutter
1. The wire cutter should be installed within the weld cell where it is
clear of all tooling and convenient for the robot to access the
unit. The base plate has been designed for mounting on top of
the TOUGH GUN Reamer. Be sure to consider movable fixtures
and the confines of the robot.
2. Attach the wire cutter base to the top of the Reamer, or other
sturdy platform using three (3) M5x0.8x25 mm long bolts in the
holes provided.
B. To Connect Air Supply
1. Use only dry filtered air.
IMPORTANT:
Requirements – 80-100 psi at 16 CFM (5.5-7.0 bar
at 450 LPM) at the wire cutter.
2. Use an air supply line with an outside diameter of 1/4” and
connect to 1/4” push-to-connect fitting located on the side of the
valve above the exhaust.
C. To Connect Power Supply
1. The TOUGH GUN TT3E Reamer Ethernet module can support the
wire cutter function and as such can be connected directly to the
reamer. Once mounted to the top of the reamer, take the 4-Pin
M12 connector and attach it to the AUX port on the Comm Plate.
2. If the Reamer is equipped with a nozzle detection system in
addition to the wire cutter, splitter part number TT3E-2343 will
be required, and will receive the 4-Pin M12 connector.
Figure 5-B
Figure 5-C
Figure 5-D
13
OM-WC-1.3