background image

 

 

PAGE 16 

MEGA 120E PUMP OPERATION / MAINTENANCE MANUAL 

4.5  PARTS LIST 

ILL 

NO 

PART NO 

QTY 

DESCRIPTION 

PM 

YEAR #

 

MATERIAL

 

BL006 

Check Bore Plug 

 

PTFE 

BL007 

Gasket Seal, Check Port 

PTFE 

BL004 

Discharge Sleeve 

 

PTFE 

98004255 

Check Ball 

PTFE 

98004258 

O-Ring 

PTFE 

BL003 

Suction Sleeve 

 

PTFE 

BL002 

Suction Seat 

 

PTFE 

BL001 

Body 

 

PTFE 

BL012 

Shaft Bushing 

PTFE 

10 

L0195 

Locking Ring 

 

PTFE 

11 

BL011 

Main Shaft 

PFA 

12 

1900B0070 

Push Plate 

 

PTFE 

13 

1900B0023 

Diaphragm Set 

PFA 

14 

98001585 

Main Seal 

Viton 

15 

L0185-01 

Head 

 

PP 

16 

L0184 

Spacer, Tie Bolt 

 

PP 

17 

BL014 

Tie Bolt Assembly 

 

SS302, PFA 

18 

L0100 

16 

Tie Bolt Cap 

LDPE 

19 

98003047 

Quick Exhaust Seal 

Viton 

20 

1900B0016 

Quick Exhaust Port 

 

UHMW 

21 

L0119 

Assembly, Muffler 

PP 

22 

98002243 

10 

Plug, 3/8 NPT 

 

PE 

23 

98003514 

Fitting, Air 

 

PP 

24 

L0140 

Bushing 

 

NPRN & 

EPDM 

25 

1900A0028-01 

Tie Bolt Washer 

 

SS316 

26 

98002341 

Nut, Flange, SS, 1/4 - 20 

 

SS18-8 

27 

98001418 

Insert 

 

SS18-8 

28 

BL017 

Pump Base 

 

PP 

29 

98001093 

Washer 

 

SS18-8 

30 

98001375 

Screw 

 

SS18-8 

31 

98001108 

Cap, Blue 

 

LDPE 

32 

98003755 

Screw, Lock Ring 

 

PTFE 

33 

98003769 

Screw, Push Plate 

 

PTFE 

34 

AW073 

End-of-Stroke Port Plug 

 

PTFE 

 

4.6  CLEAN-UP 

To help remove potentially dangerous chemicals, the pump can be flushed with DI water 

or disassembled and thoroughly cleaned. Take all appropriate safety precautions 

commensurate with the chemical risks of the fluid. 

4.7  DISASSEMBLY 

During the life of the pump it will be necessary to perform certain preventative 

maintenance procedures to ensure its continued high performance.  This section and the 

next (4.8 Assembly) are provided for the user’s convenience in disassembly and re-

assembly in performing these procedures. 

  Thoroughly clean/flush the pump using DI water (Refer to Section 4.6). 

  Remove tie bolt caps from the slave head. 

  Remove nuts from the tie bolts (Slave Head side). Leave tie bolts in place. 

  Lay the pump on its side with slave side up. 

Содержание Mega 120E

Страница 1: ...on top of product PATENTS U S 09642426 U S 06106246 U S 05971402 U S 05370507 11 72019 M120E A Phone 800 669 1303 or 801 561 0303 Fax 801 255 2312 E mail treborservice idexcorp com Mega 120E PUMP Operation Maintenance Manual ...

Страница 2: ...entive Maintenance Record 13 4 2 RECOMMENDED SPARE PARTS 14 4 3 TOOLS 14 4 4 PARTS ILLUSTRATION 15 4 5 PARTS LIST 16 4 6 CLEAN UP 16 4 7 DISASSEMBLY 16 4 7 a Quick Exhaust Muffler Disassembly 17 4 7 b Body Disassembly 17 4 8 ASSEMBLY 17 4 8 a Quick Exhaust Both Heads 17 4 8 b Body Assembly 18 4 8 c Final Assembly 21 4 9 TESTING 22 4 9 a Performance Test 22 4 9 b Dry Pump 22 4 9 c Dry Suction 22 5 ...

Страница 3: ...m both sides of all 8 tie bolts6 2 Apply 80 in lbs 9 0 N m of torque to each slave side bolt while holding the master side bolt stationary A star pattern is advised a The master side is the left side of the pump if you are looking at the fluid ports 3 Replace the tie bolt caps 1 3 UTILITIES HOOK UP The pump is mounted using four 1 4 bolts It is recommended that the pump be mounted not more than 15...

Страница 4: ...PAGE 4 MEGA 120E PUMP OPERATION MAINTENANCE MANUAL Figure 1 1 ATTENTION The pump should be operated with clean dry air or nitrogen Particulate water and oils in the air supply can damage the pump ...

Страница 5: ... discharge side of the pump 2 Although extensive efforts are made to deliver pumps to our customers completely dry new pumps may contain residual moisture from their final DI water test Recommended Maximum Operating Levels Maximum supply CDA N2 pressure 80 psig 0 55 MPa Maximum fluid temperature 212 F 100 C ...

Страница 6: ...e Options A Flare style tube adapter 1 1 4 tube fitting made of high purity PFA PVDF flare nuts standard PFA flare nuts optional B Custom fittings Contact Trebor Representative 2 2 FLUID FITTINGS SURGE SUPPRESSOR HOOK UP Surge Suppressor Assembled Height mm in SS85 434 9 17 12 SS95 382 5 15 06 Figure 2 1 ...

Страница 7: ... leak probe fitting into port See Figure 2 3 for illustration Install probe assembly into fitting Probe is self sealing and does not require a seal Tighten nut hand tight Connect fiber optic cable to sensor NOTE Minimize bends in fiber optic cable to 2 radius minimum to help ensure optimum signal strength Fiber optic cable can be cut to desired length using the cable cutter provided 2 3 b Removal ...

Страница 8: ...ANUAL 2 3 c Sensor Signal Specifications The sensor signal is normally closed In the event of a leak no light signal is returned to the sensor NOTE See your fiber optic sensor installation instructions for proper hook up and adjustment Figure 2 3 ...

Страница 9: ...ON When handling potentially dangerous fluids under pressure the pump and its fittings should be placed in an enclosure 3 1 HIGH TEMPERATURE OPERATION Pump operation at temperatures above 60 C requires periodic tightening of the tie bolt nuts The frequency of this procedure is best established by the user 3 2 PERFORMANCE CHARTS Pumping capacity is a function of air supply pressure and volume sucti...

Страница 10: ...PAGE 10 MEGA 120E PUMP OPERATION MAINTENANCE MANUAL Figure 3 2 ...

Страница 11: ... are to be shipped freight prepaid with a valid Purchase Order for the cost of rebuild service Please contact Trebor International prior to returning your pump to obtain an RMA Number and Pump Return Data Sheet to ensure proper safety precautions Each pump will be evaluated and repaired within 5 working days of the receipt of pump at Trebor facility 4 1 PREVENTIVE MAINTENANCE SCHEDULE The followin...

Страница 12: ... 24 Months Tie Bolt Torque 80 in lb I I I I I Check Seat Wear Rings R Shaft Bushing R Shaft High Suction Applications R Shaft R Diaphragms and Main Seal R Diaphragms and Main Seal HF R Diaphragms and Main Seal ACT 935 TMAH R Quick Exhaust Seal R Check Balls and O Rings R Check Balls and O Rings High Suction Applications R Exhaust Muffler Media R I Inspect R Replace ...

Страница 13: ..._ ________________________________________ Date ________ Tech _____ Notes ________________________________________ ________________________________________ Date ________ Tech _____ Notes ________________________________________ ________________________________________ Date ________ Tech _____ Notes ________________________________________ ________________________________________ Date ________ Tech...

Страница 14: ... Tie Bolt Cap BL002 2 Suction Seat BL007 2 Check Port Gasket BL009 2 Fluid Port Gasket BL012 1 Shaft Bushing L0100 16 Tie Bolt Cap In critical applications a spare pump is recommended to minimize potential down time 4 3 TOOLS The following tool kit is recommended as standard service equipment KT120 00 A Tool Kit which includes Part No Qty Description 98001230 1 5 32 Allen Wrench 98002136 2 7 16 Nu...

Страница 15: ...MEGA 120E PUMP OPERATION MAINTENANCE MANUAL PAGE 15 4 4 PARTS ILLUSTRATION Figure 4 1 ...

Страница 16: ...A0028 01 8 Tie Bolt Washer SS316 26 98002341 8 Nut Flange SS 1 4 20 SS18 8 27 98001418 4 Insert SS18 8 28 BL017 1 Pump Base PP 29 98001093 4 Washer SS18 8 30 98001375 4 Screw SS18 8 31 98001108 4 Cap Blue LDPE 32 98003755 1 Screw Lock Ring PTFE 33 98003769 2 Screw Push Plate PTFE 34 AW073 2 End of Stroke Port Plug PTFE 4 6 CLEAN UP To help remove potentially dangerous chemicals the pump can be flu...

Страница 17: ...s 4 7 b Body Disassembly Remove check bore plugs using 3 4 pin tool and remove seals Remove sleeves balls o rings and check seat Do not use excessive force Unthread push plate locking screw and push plate from the one side of the shaft Remove remaining shaft and push plate from body Unthread second locking screw and push plate from shaft Unthread shaft bushing locking screw from body Using 2 pin t...

Страница 18: ...m of the check bore Install the o ring The o ring should rest inside the cup shape in the seat Install the check ball Ensure the o ring does not become dislodged Insert the suction sleeve Press firmly using the check sleeve insertion tool until the suction sleeve meets the suction seat Install the o ring The o ring should rest inside the cup shape in the seat Install the check ball Ensure the o ri...

Страница 19: ...TION MAINTENANCE MANUAL PAGE 19 Figure 4 3 NOTE The suction sleeves are shorter than the discharge sleeves Insert the gasket seal Thread on the check port plug and tighten to 120 in lbs Repeat process for second check bore ...

Страница 20: ...ssure that the shaft bushing does not move Insert locking screw into hole and tighten until flush with locking ring Thread one push plate onto shaft until push plate bottoms out on shaft shoulder See Figure 4 5 Tighten push plate to 48 oz in and then rotate CW until locking screw hole is aligned with the next available hole in shaft The first push plate can be visually aligned separate from the bo...

Страница 21: ...n 4 4 Parts Illustration for reference Insert tie bolts into head press fit and lay head flat with tie bolts sticking up Place main seal into the main seal groove in head Install two diaphragms removing all air from between diaphragms onto the tie bolts and shuttle transfer tube Note main seal groove alignment Place body assembly onto tie bolts and head Place remaining two diaphragms onto tie bolt...

Страница 22: ...essure Check for fluid leaks listen for air leaks check for irregularity Prepare the pump for drying 4 9 b Dry Pump Connect vacuum hose to discharge line Connect purge line to fluid inlet 60 psig Supply Pressure Cycle pump vacuum dry by rotating pump side to side for 30 seconds Turn off Air Supply and allow the pump to purge for 5 minutes 4 9 c Dry Suction 20 psig Supply Pressure Target Record Suc...

Страница 23: ...ation point due to high suction requirement Increase diameter of suction supply line reduces restriction Reduce output flow Ruptured perforated diaphragm Replace diaphragms Fluid Leaks Cause Solution Tie bolt torque not enough to effect seal Tighten all nuts to 80 in lbs Damaged main seal Replace Check for irregularities in diaphragm groove on pump body Check bore cap Tighten or remove and replace...

Страница 24: ...PAGE 24 MEGA 120E PUMP OPERATION MAINTENANCE MANUAL 6 WARRANTY AND EXCLUSIONS 6 1 TREBOR STANDARD LIMITED WARRANTY https www treborintl com standard limited warranty ...

Страница 25: ...561 0303 Toll Free Number 800 669 1303 Fax Number 801 565 1510 Email treborinfo idexcorp com treborsales idexcorp com Address Trebor International 8100 South 1300 West West Jordan Utah 84088 U S A 7 2 TECHNICAL SUPPORT Email treborservice idexcorp com Phone Number 801 561 0303 7 3 REGIONAL REPRESENTATIVES Web http www treborintl com distributors ...