PAGE 22
2472 DI HEATER OPERATION / MAINTENANCE MANUAL
6
SHUT DOWN
The DI Water Heater may be shut down by the following methods:
Switch “Main Breaker” off.
Push HEATER OFF button to disengage heater element power only.
Press the EMERGENCY OFF button to deactivate the system. The
system will not turn on after a power shutdown until the EMO is
returned to the enabled position and the HEATER ON button is
pressed.
Turn off the main system circuit breaker or the facility circuit breaker.
Lockout and tagout heater for maintenance or repair. Refer to
Section 2.5.
6.1 HEATER CLEANOUT
The system has been tested with high purity DI water. After installation a
48-
hour purge “burn-in” period >1 gpm is recommended to clean out the
system and plumbing before use in high purity process applications.