Page 16 

IT-400 series instruction manual 

ENGLISH 

 

Procedure

 

IT-400 : Rotate the key to “

NIGHT

” position 

 

IT-400 K : Insert the key into the key holder for more than 5 sec. 

 

IT-400 D : Digit the access code on a keypad and press “

º

”   

  

 

During the exit time the following will take place

:  

 - The 

NIGHT

” LED on the panel and electronic key receptacle will light.   

 

If however there are zones open or unbalanced, the LED of the triggered zone on the 

 

 

panel and the “

DAY

” LED  on the panel and electronic key receptacle will light. 

 

At the end of the exit time

:

 

 

 - 

 

The 

NIGHT

” LED on the panel and electronic key receptacle will flash.         

 

 - 

 

The 

Alarm memory

” LED on the electronic key receptacle will 

go off

      -  

The control panel is now armed in "

NIGHT" 

mode. 

 

 

 
1)  Violation or unbalancing of the 24 hour, fire and panic zones, tampering of the    
 

sensors installed, insertion of false electronic key and low battery condition, will   

 

trigger the internal and external siren volt free alarm relay (Terminals 9,10,11 and 

 12,13,14,15,16,17)

 

2)   The opening or unbalancing of one of the zones  L1  L4 causes

:

  

 

Flashing on the panel of the LED corresponding to the zone triggered until the control 

 

 

panel is re-armed.    

 

Lighting of the "

DAY

" LED on the panel and electronic key receptacle until the control 

 

 

panel is re-armed. 

 

-     Activation of the indoor and outdoor siren alarm relays (Terminals

 

9 to 17) for the time 

   programmed. 
 

 

All the zones are active except those by-passed (see paragraph 13.0.). 

15.0.  PARTIAL ARMING 

(NIGHT mode)

 

If when the control panel is armed there is an open or unbalanced zone 
or low battery, the control panel will arm

 

anyway,  but  if  the  cause     

persists, at the end of the exit time, the control panel will go into alarm. 

ATTENTION 

Page 5 

IT-400 series instruction manual 

ENGLISH 

18  19  - 

L1 - Programmable Normally Closed (N.C.) immediate or delayed line.   

 

 

 

With the control panel armed, triggering this line will cause

 

 

     Flashing of the corresponding LED on the front panel until the control panel is 

 

 

  

re-armed to signal Alarm memory.  

 

 

     Lighting of the "

DAY

" LED (on the front panel and on receptacle of electronic 

 

 

  

  key) until the control panel is re-armed to signal Alarm memory. 

  

   

 

 

 Activation of the internal siren (Terminals  9,10,11)  and  external  siren      

 

 

  

   (Terminals 12 to 17) alarm relays for the pre-programmed time. 

 

    

 

  With the control panel disarmed, triggering this line will cause

 

 

     Lighting of the corresponding LED on the front panel for the time that the line 

 

 

  

is in alarm.  

 

 

  

  

What has been written above for L1 is valid for all 4 burglary alarm zones, with the only 
difference that L1 and L2 can be either programmed as delayed, and immediate while 
lines L3 and L4 are only immediate. 
 
24 - 

 

Not 

used

 

 
25  26  -   L6 

- Fire or gas alarm trigger inputs. 

 

 

With control panel armed or disarmed, triggering this line will cause

 

 

 

Flashing of the “

FIRE

” LED on the front panel until the control panel is re-armed 

 

 

 

to signal Alarm memory.  

 

 

  Activation for the pre-programmed time of the fire relay output (Terminals 3, 4, 5).  

 

 

27  28  -   L7 

- Hold-up alarm trigger input.   

   

   

With control panel armed or disarmed, triggering this line will cause

:

 

 

 

 

 

Flashing of the “

PANIC

” LED on the front panel until the control panel is          

 

 

 

re-armed to signal Alarm memory.  

 

 

 

If you have programmed a silent hold-up alarm, after this alarm has been      

 

 

 

triggered only the panic relay will activate (Terminals 6, 7, 8) for 10 seconds. 

 

   

 

If you have chosen to program the hold-up alarm with an audible alarm signal,  

 

         triggering this alarm output will activate the hold-up alarm relay terminals 6-7-&8 

                        for 10 seconds and also the internal and external sirens relays (Terminals 9 
                        through 17) for the programmed alarm time.  

          

  

 

28  29

  

-

 

L8

 - 24 hour anti-tamper trigger input.   

 

 

With control panel armed or disarmed, triggering this line will cause

 

 

  Flashing of the "

24 H

" LED on the front panel until the control panel is          

 

 

  

re-armed to signal Alarm memory 

 

 

    Activation of  the internal and external sirens relays (Terminals 9 through 17) for 

                        the programmed alarm time.  

 

Содержание IT-400

Страница 1: ...indicates control panel armed day position This is located on the remote electronic key base see page 10 36 Output for remote LED that indicates alarm memory This is located on the remote electronic...

Страница 2: ...relay alarm outputs Separate relay alarm outputs for internal sirens Remote indication for unit ON Low battery indication Output for siren with or without battery back up Relay output for panic an fi...

Страница 3: ...mains fuse and if the battery charger is functioning correctly 13 8 Vdc on cables of battery If all functions correctly then the battery must be replaced Please dispose of faulty batteries in an envir...

Страница 4: ...C Outdoor siren relay 33 Buzz Remote Key Impulse Remote Key ON OFF Page 17 IT 400 series instruction manual ENGLISH To disarm the panel IT 400 Rotate the key in DAY position IT 400 K Insert the key in...

Страница 5: ...e will cause Flashing of the corresponding LED on the front panel until the control panel is re armed to signal Alarm memory Lighting of the DAY LED on the front panel and on receptacle of electronic...

Страница 6: ...g the exit time the following will take place The ON LED on the panel and electronic key receptacle will light If however there are zones open or unbalanced the LED of the triggered zone on the panel...

Страница 7: ...the control panel to DAY mode 13 0 BY PASSING ZONES It is possible to partially arm the system NIGHT mode by by passing some of the zones NOTE The control panel is supplied with all the zones active P...

Страница 8: ...ight 1 Off signals line closed normal status 2 Flashing indicates zone in alarm or alarm memory L BAT FIRE PANIC AS POWER L BAT FIRE PANIC AS POWER L1 L2 L3 L4 L1 L2 L3 L4 D C A B ON DAY ON NIGHT DAY...

Страница 9: ...the cover of the control panel making sure that dip 1 of dip switch A is in OFF position normal function and that the tamper button is closed Page 9 IT 400 series instruction manual ENGLISH ATTENTION...

Страница 10: ...0 K to the terminals on the back side of the receptacle as shown in the figure on the right Control panel armed ON Control panel armed Night Remote receptacle Electronic key Control panel disarmed DAY...

Отзывы: