background image

Page 14 

IT-400 series instruction manual 

ENGLISH 

ATTENTION 

As you enter the 5th phase, the panel will show how 
zone 1 (L1) is set (L1 is always “ON” or flashing).  

  

Visualization of the configuration memorized

 

 

 IT-400 

IT-400K

   -   Turn the key of the control panel to the "

NIGHT

" position  

 

 

 

and during the exit time, press any one of the buttons  

 

 

 

A

”,.“

B

”, “

C

” or “

D

" relative to the zones.

 

 

 

 

IT-400 D    

-   Bring the control panel to the "

NIGHT

" mode by digiting the access 

 

 

code followed by “

º

”  and during the exit time  press “

#

”. 

 
 

The control panel will visualize the present state of the zones programmed for Night arming. 

 
 

 

If the 

LED

 related to the zone is 

lit

,

 

the zone is active in “NIGHT” mode. 

 

 

If the 

LED

 related to the zone is 

OFF

, the zone is by-passed in “NIGHT” mode. 

 

   

To modify the configuration memorized

 

 

 

 

To modify the memorized configuration, press buttons “

A

”, “

B

”, “

C

” or “

D

” related  

 

to the zones. The LED will change status from lit to off or viceversa. 

 

    

To memorize a configuration

 

 
 

At the end of configuration, switch the control panel to the "

DAY

" mode for memorization. 

 

 

IT-400 / IT-400 K 

-  Turn the key of the control panel to the "

DAY

" position. 

 

IT-400 D    

-   Digit “

#

” to bring the control panel to "

DAY

" mode. 

13.0.  BY-PASSING ZONES 

It is possible to partially arm the system (NIGHT mode) by by-passing some of the zones. 

NOTE   The control panel is supplied with all the zones active

.   

Page 7 

IT-400 series instruction manual 

ENGLISH 

  

One  of  the  two  phases  of  the  mains  power  is  protected  by  a             

delay action fuse T800 mA. 
  The fuse is incorporated in the terminal block seen on the right hand 
side.  
  In case of fuse burn out it can be easily changed by pulling           
upward the fuse holder as shown on the right.  
  Change the fuse and plug it back in with downward pressure.   
 

    

  It is important to have a good ground connection to avoid electrical             
disturbances to the control panel. Therefore the terminal indicated as 
ground (see on the right)

 

must be connected to a good ground 

connection

4.0.  MAINS POWER CONNECTION 

Ground 

connection 

Presence of main power is indicated on the front panel when the green “POWER” LED lights 
up. 

  

Before making this connection be 

sure that cable 

being use is volt free

 and insert the bare wire on 

the cable used completely into the terminal block as 
seen on the right.  

 
 

Electrical building installation must be equipped with a bipolar automatic switch.    
In case of ordinary maintenance, disconnect the unit from the mains.  

4.1.  MAINS POWER FUSE CHANGE  

4.2.  GROUND CONNECTION  

ATTENTION 

NO 

YES 

Содержание IT-400

Страница 1: ...indicates control panel armed day position This is located on the remote electronic key base see page 10 36 Output for remote LED that indicates alarm memory This is located on the remote electronic...

Страница 2: ...relay alarm outputs Separate relay alarm outputs for internal sirens Remote indication for unit ON Low battery indication Output for siren with or without battery back up Relay output for panic an fi...

Страница 3: ...mains fuse and if the battery charger is functioning correctly 13 8 Vdc on cables of battery If all functions correctly then the battery must be replaced Please dispose of faulty batteries in an envir...

Страница 4: ...C Outdoor siren relay 33 Buzz Remote Key Impulse Remote Key ON OFF Page 17 IT 400 series instruction manual ENGLISH To disarm the panel IT 400 Rotate the key in DAY position IT 400 K Insert the key in...

Страница 5: ...e will cause Flashing of the corresponding LED on the front panel until the control panel is re armed to signal Alarm memory Lighting of the DAY LED on the front panel and on receptacle of electronic...

Страница 6: ...g the exit time the following will take place The ON LED on the panel and electronic key receptacle will light If however there are zones open or unbalanced the LED of the triggered zone on the panel...

Страница 7: ...the control panel to DAY mode 13 0 BY PASSING ZONES It is possible to partially arm the system NIGHT mode by by passing some of the zones NOTE The control panel is supplied with all the zones active P...

Страница 8: ...ight 1 Off signals line closed normal status 2 Flashing indicates zone in alarm or alarm memory L BAT FIRE PANIC AS POWER L BAT FIRE PANIC AS POWER L1 L2 L3 L4 L1 L2 L3 L4 D C A B ON DAY ON NIGHT DAY...

Страница 9: ...the cover of the control panel making sure that dip 1 of dip switch A is in OFF position normal function and that the tamper button is closed Page 9 IT 400 series instruction manual ENGLISH ATTENTION...

Страница 10: ...0 K to the terminals on the back side of the receptacle as shown in the figure on the right Control panel armed ON Control panel armed Night Remote receptacle Electronic key Control panel disarmed DAY...

Отзывы: