Cove Light AC HO RGB Graze
INSTALLATION GUIDE
V0.1
Cover:
Cove Light AC HO-9 RGB Graze
Cove Light AC HO-36 RGB Graze
Страница 1: ...Cove Light AC HO RGB Graze INSTALLATION GUIDE V0 1 Cover Cove Light AC HO 9 RGB Graze Cove Light AC HO 36 RGB Graze ...
Страница 2: ...cifications are subject to change without notice Installation Guide 06 15 V0 1 2 of 15 CONTENT 1 INTRODUCTION 3 2 installation 6 3 Safety And Operation 10 4 SYSTEM CONFIGURATION 11 5 Care and Maintenance 12 6 TECHNICAL SPECIFICATION 13 7 Troubleshooting 14 8 Warranty Statement 14 For your own safety and that of the product please read this installation guide carefully before beginning setup and in...
Страница 3: ...rfect for alcove applications The simplicity of the luminaire s topology means it can be simply daisy chained to form long runs Cove Light AC HO RGB Graze is suitable for a wide range of lighting applications from alcove to indirect illumination in architecture hospitality and retail shops Plug n Play cabling and connection makes installation quick and easy Model Number of LED Power Consumption W ...
Страница 4: ... 8 2 223mm 8 8 90 38mm 1 5 60mm 2 4 12 5mm 0 49 5 3mm 0 2 3 3mm 0 13 12 5 3mm 0 2 3 3mm 0 13 304mm 12 209mm 8 2 223mm 8 8 90 38mm 1 5 60mm 2 4 12 5mm 0 49 5 3mm 0 2 3 3mm 0 13 304mm 12 223mm 8 8 209mm 8 2 38mm 1 5 60mm 2 4 90 Cove Light AC HO 36 RGB Graze FIG 2 12 8 2 8 8 90 38mm 1 5 60mm 2 4 12 5mm 0 49 5 3mm 0 2 3mm 0 13 12 5mm 0 49 5 3mm 0 2 3 3mm 0 13 304mm 12 209mm 8 2 223mm 8 8 90 38mm 1 5 6...
Страница 5: ...tx connect are trademarks of traxon technologies u s patents e u patents japan patents other patents pending specifications are subject to change without notice Installation Guide 06 15 V0 1 5 of 15 Packing Contents 1 3 Packing Contents FIG 3 Cove Light AC HO RGB Graze x1 Washer x4 ST 3mm x 25mm x4 ...
Страница 6: ...tion of data injectors and fixtures Distance between data 1 injector and first fixture should not be more than the limit specified in mounting guide system diagram In case it is in doubt consult your local Traxon office or authorized agent All fixtures must be installed in daisy chain Do not connect fixtures as a star connection 2 Correct Installation Topology FIG 4 Data Injector Data Injector Eac...
Страница 7: ... content against the packing 1 contents provided in Installation Guide Check the content for any visual damage or defect Check the voltage rating of the fixtures Report any defect found to your nearest Traxon office or authorized agent DO NOT 2 attempt to install any fixture with defects Cable Bending 2 2 3 Cable must NOT be bent below the Minimum Bending Radius as specified by cable manufacturer ...
Страница 8: ...e cable Failure to keep Cove Light AC HO RGB Grazes within the operating temperature range of 20 C to 45 C 4 F to 113 F and storage temperature range of 40 C to 70 C 40 F to 158 F will void the product s warranty Wall Installation 2 3 1 Unplug the end cap from data injector and mount it 1 Unplug End Cap FIG 7 D A T A O U T T O F IX T U R E A C IN D A T A IN Make sure power is off Connect the start...
Страница 9: ...ture to data injector then rotate the fixture to mount it Make sure that 3 the male connector is connected to the female connector of mounted fixture Connect first fixture to data injector FIG 9 Connect and mount other fixtures one by one 4 Connect rest of the fixtures FIG 10 Use interconnection cable if fixtures are not adjacent to each other Plug the end cap to 5 the final fixture of the chain t...
Страница 10: ...product is designed for indoor and outdoor use Ensure product operates within the specified temperature range Refer to 6 TECHNICAL SPECIFICATION for more details Do not attempt to open the product Not user serviceable Do not use the product if any part of it or the power cables are damaged Only use product for specified voltage do not exceed Refer to 6 TECHNICAL SPECIFICATION for more details Alwa...
Страница 11: ...s patents e u patents japan patents other patents pending specifications are subject to change without notice Installation Guide 06 15 V0 1 11 of 15 SYSTEM CONFIGURATION 4 System Diagram FIG 12 Data Injector AC In DMX In DMX Out RJ45 connection Female connector Male connector Use end cap for final fixture in chain TO FIXTURE AC IN DATA IN DATA OUT ...
Страница 12: ...property damage Do not use product s if cables are damaged Do not connect cables and connectors when wet or in wet area Moisture on bare connectors can cause electric shock and damage to product s Do not use product s in extreme heat environment Ensure there is sufficient airflow and use cool air circulation if required Do not drop knock or shake product s Rough handling can damage the electronics...
Страница 13: ...y impossible to expect photometric performances of two LED products with different service life spans to be the same The rate of LED degradation is a complex function of many factors such as operating efficiency duration of continuous operation and operating conditions e g ambient temperature Because LEDs are semiconductor devices their performances are subject to inherent variability commonly fou...
Страница 14: ...or cables wires or unwanted debris covering LED light source Modules are dim Excess products connected Ensure the power supplies are not overloaded due to an excess of products connected Flickering Incorrect power input Excess products connected Ensure the input voltage is correct Ensure the power supplies are not overloaded due to an excess of products connected If problems persist or the product...
Страница 15: ...Please check for the latest updates and changes on the Traxon website 2015 TRAXON TECHNOLOGIES ALL RIGHT RESERVED Information is subject to change without prior notice www traxontechnologies com ...