20 Installation
(for qualified installers only)
Travis Industries
4070620
100-01199_000
Wall Switch or Thermostat Installation
Wiring Diagram (Millivolt System)
Do not connect 110-240 VAC to the gas control valve or wiring system of this fireplace. The switch must
be installed by a qualified installer.
The included wall switch may be installed following the directions below. An optional thermostat may also
be installed. It is attached to the gas control valve in the same manner.
Caution
:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Wall Switch Installation
1. Attach the included wire to the gas control valve.
2. Determine a location for the wall switch (the wire is a maximum 7.6m long). Route the wire through the
gas inlet hole (either side) to the junction box and attach following the directions below. Set the on/off
switch on the appliance to "OFF" to control the appliance with the wall switch.
Orange
White
Piezo Igniter
Thermopile
Red
Thermocouple
Copper Co-Axial
Wire
Red
Spark Electrode
Pilot Hood
On/Off Switch (on fireplace)
Optional Wall Switch,
Thermostat, or
Remote Control
Brown
Attach the two wires to the top and
bottom posts on the gas control
valve (orientation does not matter).
a
Carefully pack the wires into the
junction box. Attach the switch
to the junction box. Attach the
switchplate to the switch.
b
Standard
Screwdriver
From
Appliance
Insert the wire
through the back of
the mounted
junction box (your
junction box may
look different).
Expose 1/2" of
each wire. Secure
the wires to the
posts on the side of
the on/off switch
(orientation does
not matter).
Standard
Screwdriver
Expose 13mm of