12 Installation
(for qualified installers only)
Travis Industries
4070620
100-01199_000
Minimum Framing Dimensions - Rear Vent Configuration
24-1/4"
36-1/2"
33-1/2"
16-1/2"
Route the
electrical line to
a position to the
left rear of the
fireplace.
Vent Clearances (8" dia. Vent):
1" to the sides, 1" below, and 4" above
the vent to combustibles.
Included Firestop (required)
Part # 250-00747
Center of Rear Vent
HINT
: place the fireplace so the center
line is at least 5" from both vertical framing
members at the rear (this allows the vent
to pass through the framing without
modfications)
The on/off switch/thermostat wire (if
used) should be routed to a location
near the right front of the fireplace.
Minimum 38” Fireplace
Enclosure Height
19-1/4"
32-1/2"
HINT
: place the fireplace so the center
line is at least 130mm from both vertical
framing members at the rear (this allows
the vent to pass through the framing
without modifications)
Vent Clearances (205mm dia. Vent):
25mm to the sides, 25mm below, and
100mm above the vent to combustibles.
Minimum 865mm Fireplace
Enclosure Height
615mm
825mm
850mm
930mm
420mm
490mm