Installation (for qualified installers only)
15
© Travis Industries
4140811
100-01340
Exhaust Restrictor
Restrictor adjustment should only be done by a qualified installer.
Set the exhaust restrictor to the position shown in the table below.
NOTE:
The appliance will slow down within 5 to 10 minutes of startup due to the bi-metallic damper
closing. Make sure to wait for at least 10 minutes before assessing flame quality.
NOTE:
The restrictor positions listed below are based upon laboratory testing. The optimum position may
vary slightly.
Restrictor Settings
Traditional Logs
Natural Gas Short Vent (25’ or less)
#3 (stock position)
Natural Gas Tall Vent (25’ or more)
#4
Propane Short Vent (25’ or less)
#2
Propane Tall Vent (25’ or more)
#4
# 1
# 2
# 3 (stock)
# 4
# 5
Back Wall of Insert