BEFORE YOU START
Tie the cuff
2~3cm
1.
4.
Hold your arm with your palm facing up and
tie the cuff on your upper arm, then position
the tube off-center toward the inner side of
arm in line with the little finger. Or position the
artery mark over the main artery (on the
inside of your arm). Note: Locate the main
artery by pressing with 2 fingers
approximately 2 cm above the bend of your
elbow on the inside of your left arm. Identify
where the pulse can be felt the strongest.
This is your main artery.
The cuff should be snug but not too tight.
You should be able to insert one finger
between the cuff and your arm.
Remove all jewelry, such as watches and
bracelets from your left arm.
Note: If your doctor has diagnosed you with
poor circulation in your left arm, use your right
arm.
Roll or push up your sleeve to expose the
skin. Make sure your sleeve is not too tight.
2.
3.
5.
Sit comfortably with your tested arm resting on a
flat surface. Place your elbow on a table so that
the cuff is at the same level as your heart. Turn
your palm upwards. Sit upright in a chair, and take
5-6 deep breaths.
Rest for 5 minutes before first measuring.
Wait at least 3 minutes between measurements.
This allows your blood circulation to recover.
The patient must relax as much as possible and do
not move and talk during the measurement procedure.
For a meaningful comparison, try to measure under
similar conditions. For example, take daily
measurements at approximately the same time, on the
same arm, or as directed by a physician.
6.
Take the measurement in a silent room.
The cuff should maintain at the same level as the
right atrium of the heart.
Please sit comfortably. Do not cross your legs and
keep your feet flat on the ground.
Keep your back against the backrest of the chair.
Helpful tips for Patients, especially for Patients with
Hypertension:
RF Frequency Range:
2402 MHz to 2480 MHz
Maximum output power:
2.7dBm
Supply Voltage:
1.8-4.5 V
Transmitting Distance:
10 meters
CAUTION
1.
2.
Interference may occur in the vicinity of equipment marked with the following
symbol . And TMB-2079 may interfering vicinity electrical equipment.
Sensitive people, including pregnant women pre-eclamptic and those who
implanted medical electronic instruments, should avoid using the unit
whenever possible.
Keep the monitor at least 20 centimeters away from the human body
(especially the head) when the data transmission is proceeding after
measurement.
To enable the data transmission function, this product should be paired to
Bluetooth end at 2.4 GHz.
How to mitigate possible interference?
The range between the device and BT end should be reasonably close, from
1 meter to 10 meters. Please ensure no obstacles between the device and
BT end so as to obtain quality connection and to lower the RF output range.
To avoid interference, other electronic devices (particularly those with
wireless transmission / Transmitter) should be kept at least 1 meter away
from the monitor.
List of compatible devices
:
For iOS devices:
The operating system must be iOS 11.0 or more.
For Android devices
The operating system must be Android 8.0 or more
MEASUREMENT
16