background image

INTRODUCTION

...............................................................

2

Indications for Use

LCD Display Signal

Monitor Components

BEFORE YOU START

..........................................................

8

MEASUREMENT

...............................................................

15

INFORMATION FOR USER

......................................................

20

Tips for Measurement

Maintenance

ABOUT BLOOD PRESSURE

.....................................................

22

What are systolic pressure and diastolic pressure?

What is the standard blood pressure classification?

Why does my blood pressure fluctuate throughout the day?

Why do I get a different blood pressure at home compared to the hospital?

Is the result the same if measuring on the right wrist?

TROUBLESHOOTING

.........................................................

24

SPECIFICATIONS

.............................................................

25

CONTACT INFORMATION

......................................................

26

Safety Information

 

Start Measurement

Data Management

.....................................

17

.........................

COMPLIED STANDARDS LIST 

....................................

27

Table of Contents

...............

Measurement Principle

General Description

EMC GUDIANCE

......................................................

28

......

Positioning the Cuff

Pair up the Blood Pressure Monitor with Your Device

Recall the Records
Delete the Records

1

Table of Contents

Installing and Replacing the Batteries

Setting Date, Time, Positioning Symbol and Measurement Unit

Setting the User ID

Содержание TMB-1598-BS

Страница 1: ...age of this product and keep the manual well for your further reference in case you have problems Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB 1598 BS Wrist Type Version 1 0 G...

Страница 2: ...blood pressure at home compared to the hospital Is the result the same if measuring on the right wrist TROUBLESHOOTING 24 SPECIFICATIONS 25 CONTACT INFORMATION 26 Safety Information Start Measurement...

Страница 3: ...devices patients with pre eclampsia premature ventricular beats atrial fibrillation peripheral arterial disease and patients undergoing intravascular therapy or arterio venous shunt or people who rec...

Страница 4: ...and remove it from your wrist If the cuff pressure reaches 40 kPa 300 mmHg the unit will automatically deflate Should the cuff not deflate when pressures reaches 40 kPa 300 mmHg detach the cuff from t...

Страница 5: ...he average value of blood pressure User 1 Indicate the blood pressure level Blood pressure level indicator Start measurement and save the results for user 1 User 2 Start measurement and save the resul...

Страница 6: ...idelines The typical service life of the new and unused batteries is 54 measurements for the operation time is 60s 1 2 3 It is important to set the clock before using your blood pressure monitor so th...

Страница 7: ...steps 2 and 3 to confirm Positioning symbol on or off 6 Repeat steps 2 and 3 to confirm the measurement unit 7 After confirming the meausrement unit the LCD will display donE then display all the set...

Страница 8: ...st cuff around your wrist leaving no extra room between the cuff and your skin If the cuff is too loose the measurement will not be accurate Sit comfortably with your tested wrist resting on a flat su...

Страница 9: ...l display User ID donE and then turn off Then you can start your measurement now 2 1 Adjust the zero LCD display Inflating and measuring Display and save the result The year date and time will dispaly...

Страница 10: ...cinity of equipment marked with the following symbol And TMB 1598 BS may interfering vicinity electrical equipment Sensitive people including pregnant women pre eclamptic and those who implanted medic...

Страница 11: ...confirm Then press button to check the records of the selected user 3 1 If you did not get the correct measurement you can delete all the results for the selected user by following steps Take user 1 f...

Страница 12: ...t Immediate measurement after tea coffee smoking When talking or moving your fingers When you want to discharge urine Maintenance In order to get the best performance please follow the instructions be...

Страница 13: ...ths before beginning will be better for measuring Advice Relax yourself for 4 5 minutes until you calm down It is ok for both wrists but there will be some different results for different people We su...

Страница 14: ...your monitor with your mobile device Please check below items Bluetooth is ON App Collector is ON Both devices are within the transmission distance of Bluetooth Power supply Battery powered mode 2 AA...

Страница 15: ...anagement to medical devices EN 1041 2008 Information supplied by the manufacturer of medical devices EN 60601 1 2006 IEC 60601 1 2005 A1 2012 Medical electrical equipment Part 1 General requirements...

Страница 16: ...hat supplies buildings used for domestic purposes Guidance and manufacturer s declaration electromagnetic immunity Immunity test 8 kV contact 15 kV air 8 kV contact 15 kV air 2 kV power supply lines l...

Страница 17: ...quency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths f...

Страница 18: ...960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18Hz 2 0 3 28 1720 1845 1970 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation b 217Hz 2 0 3...

Отзывы: