Safety and Usage Information

Safety Information

Safety Information

     Transtek’s Body Fat Analyzer LS202-B1 offers you a seamless way to manage your 

health. Please be aware that this device is designed for healthy population over 10 years old 

self-measuring and self-monitoring body compositions. Any information provided by this 

device is in no way meant to treat, cure or prevent any disease or illness from happening. 

If in doubt, contact your physician.

     This device is contraindicated for any female subject who may be suspected of, or is 

pregnant. Otherwise, the effects of this device on the fetus are unknown.

     This device is contraindicated for any person who is connected to a wearable or implantable 

electronic device or instrument such as a pacemaker or defibrillator.

     This device should not be used for anyone who is acutely or chronically ill because of 

suffering from a disease or taking medications that affect your water levels. The accuracy of 

readings for these patients has not been verified. Specific medical advice should be obtained 

from a physician.  

     LS202-B1 is equipped with data transmission function. It may emit electromagnetic 

energy so as to perform its intended function. Nearby portable and mobile RF communications

equipment can affect the performance of LS202-B1. And the device can interfere vicinity 

electrical equipment.

      Manufacturer will make available on request circuit diagrams, component parts list,etc.

     WARNING:No modifications of this equipment is allowed. This may result in increased 

EMISSIONS or decreased IMMUNITY of LS202-B1.

     Please use the device according to the user manual. Any misuse can cause electric shock,

burns, fire and other unexpected hazards.

    Please use and storage the device under the environment which was provided in the user 

manual. 

    Don’t expose the device to extreme temperatures, direct sunlight, moist or corrosive 

environment.

    Do not step on the scale when your body or feet are wet, especially after bathing or 

showering to prevent slipping.

CAUTION

Symbol for “THE OPERATION 

GUIDE MUST BE READ”

Symbol for “MANUFACTURER”

Symbol for “ENVIRONMENT 

PROTECTION – Waste electrical 

products should not be disposed of with 

household waste. Please recycle where 

facilities exist. Check with your local 

authority or retailer for recycling advice”

Symbol for “TYPE BF APPLIED 

PARTS” 

The Bluetooth Combination Mark

Symbol for “SERIAL NUMBER”

Symbol for “MANUFACTURE 

DATE”

Symbol for “DIRECT CURRENT”

INDICATIONS FOR USE

The Transtek Body Fat Analyzer measures weight and uses bio-electrical impedance analysis 

(BIA) technology to estimate body fat, total body water percentage, bone mass, and muscle 

mass in generally healthy children 10-17 years old and healthy adults. 

It is intended for use in the domestic setting only. 

Tips

To ensure the accuracy of measurement, please follow below instructions when 

you start measurement.

Place the scale on a flat, hard surface. Soft surface such as carpet will affect the 

performance of the scale.
Step onto the platform with bare feet. Stand still and keep full contact with the electrodes 

until the measurement is complete.
Start measurement at least two hours after Getting up or Dinning.
Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and 

dinning.
Always start measurement in the same time slot and on the same scale located on the 

same flat, hard surface.

For maximum accuracy and repeatability , it is recommended that you should use the 

device in the same time of the day and on the same location. 

Body fat percentage estimates will vary with the amount of water in the body, and can 

be affected by dehydration or over-hydration due to such factors as alcohol consumption, 

menstruation, illness, intense exercise, etc.

The condition of the skin on the bottom of your feet can affect the reading. The natural 

effects of aging or activity can make this skin hard. Take the reading with clean, slightly 

damp feet for best accuracy. If you are having a problem on operating this scale please 

contact customer service.

  To prevent you from injury, please pay attention to the following Notice.

A list of known devices or other sources that can potentially cause interference problems 

(example 1  Heat from a fireplace or radiant heater.  example 2  Moisture from a nebuliser 

or steam kettle). 

Small parts being inhaled or swallowed. 
Potential allergic reactions to accessible materials used in the ME EQUIPMENT. 
Contact injuries.  
Use accessories, detachable parts and materials not described in the instructions for use. 

The effects caused by pets, pests or children.

The effects of degraded sensors and electrodes, or loosened electrodes, that can degrade 

performance or cause other problems. 

Содержание LS202-B1

Страница 1: ...37 China TEL 86 760 88282982 www transtek cn User Manual Body Fat Analyzer LS202 B1 Please do read the user manual carefully and thoroughly so as to ensure the safe usage of this product and keep the...

Страница 2: ...on Start Measuring First Measurement Daily Measurement Fast Measurement Clear Your Profile Manage Your Health Body Fat Indicator Data Transmission Troubleshooting Error Prompt When Measuring When Data...

Страница 3: ...ROTECTION Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local authority or retailer for recycling advice Symbol for TYP...

Страница 4: ...le Male Athlete Female User ID Range from U1 to U8 Successful Bluetooth Connection Data transmitting pending to transmit to wireless wellness system Low Battery LCD Display Body Mass Index List 1 Body...

Страница 5: ...a Turn on Bluetooth and the App Make sure both are ON when pair up is proceeding Press and hold UNIT button in the back of the scale to start pair up Symbol and symbol will be shown on the LCD alterna...

Страница 6: ...erator may touch the function key or to increase or decrease the numeral Range 10 to 85 years old You may touch and hold the function key or for fast changing the numeral Touch SET key to confirm Age...

Страница 7: ...reading scale No special programming steps are required Once the scale is initialized as previously described you may simply step on the scale to measure your current weight For only weight reading 1...

Страница 8: ...ID with most similar history records Then the measuring results will be displayed sequentially four times and then turn off When the system finds out two or more users with similar history records th...

Страница 9: ...ce 1 The range between the Analyzer and the Bluetooth end should be reasonably close from 1 meter to 10 meters Please ensure no obstacles between the Analyzer and the Bluetooth end so as to obtain qua...

Страница 10: ...ater muscle mass and bone mass The device powers off Wipe your feet with a damp cloth keeping them slightly damp when starting measurement Batteries not yet installed Worn batteries Low battery Instal...

Страница 11: ...ice DON T wash the device with water or immerse it in water DON T use propellant abrasive or other chemicals to wipe the dirt in avoidance of discolor or malfunction DON T disassemble this device If y...

Страница 12: ...d void the user s authority to operate the equipment FCC RF Exposure Guidelines Safety Information Reducing RF Exposure Use Properly Only operate the device in accordance with the instructions supplie...

Страница 13: ...hat the device be powered from an uninterruptible power supply or a battery Guidance and manufacturer s declaration electromagnetic immunity The device is intended for use in the electromagnetic envir...

Страница 14: ...device is intended for use in the electromagnetic environment specified below The customer or the user of the device should assure that it is used in such an environment Portable and mobile RF communi...

Отзывы: