11
Chapter 3 - Connection
ServoPac GDPS – Power supply unit
Chapter 3 – Connection
3.1 – CONNECTION DIAGRAM
3
x
400Vac
Q1: Circuit breaker type D
I1s = 10 x In
GDPS16 = 20 A
GDPS32 = 40 A
F1: Optional fuse / mandatory for UL
KM1: Mains contactor
DC+
DC-
TT GDPS-400/xx
X2
X1
1 2 3 4
1 2 3 4 5 6 7
DC+
DC-
Q1
AXIS 1
AXIS N
TT drive
TT drive
Brak
ing
resist
or
AC
24V
isolat
e
d
-
+
230 V
0 V 24 V A
OK+
AO
K-
L1
L2
L3
DC- DC+ DR+ DR-
Power
ON
Power relay
remote control
KM1
24 V
AOK GDPS
+
+
+
-
-
-
AOK AXIS 1
AOK AXIS N
STOP
km1
KM1
F1
3.2 – FUSE RATING
For the ServoPac GDPS-400/xx multi-axis power supply unit:
ServoPac GDPS
400/16
400/32
FERRAZ
A60Q20-2
A60Q40-2
Polarity DC+ and DC- between drives and the TT GDPS power supply unit must be observed.
Otherwise, drives will be immediately destroyed.
AOK input must be wired in order to reduce the risk of fire.
Содержание ServoPac GDPS