ICE-‐ENTRY-‐100
INSTALLATION MANUAL
Page 16
♦
Remote programming by SMS
;IN1=0;IN2=4;ID1=10;ID2=0;DD1=0;DD2=15;
9.1.2 REMOTE REPORTING ALARM EVENTS
Parameters used to define the way to report the alarm event.
NOTE
ICE-ENTRY-100 device send SMS messages for reporting alarm events.
9.1.2.1
TN parameter
Telephone numbers for remote alarm reporting are listed as TN parameters.
Remote alarm reporting on ICE-ENTRY-100 is done via SMS messages.
9.1.2.2
LN parameter
This parameter is used to link alarm event from inputs or any other source to the
telephone numbers from TN list.
9.1.2.3
LOT parameter
LOT parameter is used to define the time control for voice calls. The start of voice
connection starts the LOT timer. If the voice connection is still ON when the LOT
timer expires ICE-ENTRY-100 disconnects voice connection.
9.1.2.4
Table of parameters
Name
Comment
TN1
1
st
telephone number
TN2
2
nd
telephone number
TN3
3
rd
telephone number
TN4
4
th
telephone number
TN5
5
th
telephone number
LN1
Input & telephone No. linking for 1
st
alarm input (TN1 –
Содержание iCE?Entry?100