Features 

 

External AC power supply 

 

IEEE 802.3af Power Over Ethernet compatible 

 

48 VDC PSE output voltage 

 

Applies power on the data pairs (aka Alt A, or Mode A) 

 

PD Detection Signature 

 

Over-Current Protection and Under-Current Detection 

 

Powered Device (PD) Reset 

 

PD Detection Signature 

 

Minimum Load Sensing 

 

Fault Protection Input 

 

Auto-Negotiation (802.3u): allows devices to perform automatic configuration to achieve the best possible 
mode of operation over a link. 

 

AutoCross

: automatically detects and configures the twisted pair port to the correct MDI or MDI-X 

configuration. 

 

Link Pass Through (LPT): a troubleshooting feature that lets the media converter monitor both fiber and 
copper RX ports for loss of signal. 

 

Far End Fault (FEF):  a troubleshooting feature generally used with Link Pass Through to notify both end 
devices of a loss of link. 

 

Automatic Link Restoration: lets Transition Networks' converters automatically re-establish link in all 
network conditions.  

Application Example - Power over Cat5 to Remote Devices 

 

Packing List 

Make sure that you have received the following with your SPOEB10xx-105: 

 

One SPOEB10xx-105 Media Converter 

 

One external power supply (25072) and power cord (25071) 

 

Four rubber feet 

 

One printed Documentation Post Card

 

Please save the packing material for possible future use. 

 

 

Содержание SPOEB1011-105

Страница 1: ...Devices 3 Packing List 3 Installation 4 Set the Configuration DIP Switch 4 Eight position Configuration Switch SW1 4 Additional Features 6 Far End Fault always enabled 6 Automatic Link Restoration always enabled 6 Installing Fiber Cables 7 Installing the Copper Cable 7 Connecting Power 8 Operation 9 Status LEDs 9 PoE Status LED Scheme 9 Cable Specifications 10 Copper Cable 10 Fiber Cable 10 Fiber ...

Страница 2: ...ures as well as force port capabilities In addition with the PSE LPT switch enabled a loss of Fiber RX will disable PSE power output on the UTP port for two seconds to allow the remote device to re initialize The PoE converter is fully compatible with devices that comply with the IEEE802 3af standard The PoE converter is capable of inserting power on data pairs of the MDI Product Description Model...

Страница 3: ...figures the twisted pair port to the correct MDI or MDI X configuration Link Pass Through LPT a troubleshooting feature that lets the media converter monitor both fiber and copper RX ports for loss of signal Far End Fault FEF a troubleshooting feature generally used with Link Pass Through to notify both end devices of a loss of link Automatic Link Restoration lets Transition Networks converters au...

Страница 4: ... Down TP Half Duplex only when TP Autoneg disabled 4 FBR Duplex Up FBR Full Duplex Down FBR Half Duplex 5 LPT Select Up LPT Enabled Down LPT Disabled 6 PSE Select Up PSE Enabled Down PSE Disabled 7 PSE LPT power off LPT Up Disabled Down Enabled 8 Reserved 1 TP Auto Negotiation Up Enables Auto Negotiation Down Disables Auto Negotiation The Auto Negotiation feature allows the media converter to brin...

Страница 5: ...otified of the link loss which prevents the loss of valuable data unknowingly transmitted over an invalid link See diagram below 6 PSE Power Up Enables PSE power Down Disables PSE power The IEEE 802 3af standard allows a device to provide power PSE Power Sourcing Equipment to a remote device and for a remote device PD Powered Device to accept and use this power over a twisted pair interface 7 PSE ...

Страница 6: ... notified automatically of the link loss Prevents loss of valuable data transmitted unknowingly over invalid link Allows quick diagnosis and resolution of network problem Transition Networks media converters that include the FEF feature will work with other network devices that support Far End Fault per IEEE standards Automatic Link Restoration always enabled Transition Networks converters will au...

Страница 7: ...port Connect the male RX cable connector to the female RX port 3 Connect the fiber cables to the other device another media converter hub etc as follows Connect the male TX cable connector to the female RX port Connect the male RX cable connector to the female TX port Installing the Copper Cable 1 Locate 100Base TX copper cables with male RJ 45 connectors installed at both ends 2 Connect the RJ 45...

Страница 8: ...verter back panel 2 Connect the power adapter plug to AC power 3 Verify that the front panel PWR LED is lit indicating the SPOEB is powered External 90 250 VAC Power Supply TN 25072 US Power Cord 25071 and SPOEB Power Supply Included To order the corresponding country specific power supply add the Country Code extension to the end of the SKU NA North America LA Latin America EU Europe UK United Ki...

Страница 9: ... Blinking activity SPD TP TP Speed Green ON 100Mb s OFF 10Mb s DPX TP TP Duplex mode Green ON Full OFF Half Blinking collision POE STAT Power over Ethernet State Green ON Enabled OFF Disabled LACT Link Activity DPX Duplex SPD Speed TP Twisted Pair LTC PoE controller PoE Status LED Scheme The PoE controller component provides the following LED reporting LED Condition Meaning LED Off Non Powered Dev...

Страница 10: ... optic transmitters on this device meet Class I Laser safety requirements per IEC 825 CDRH standards and comply with 21 CFR1040 10 and 21CFR1040 11 Fiber Specifications SPOEB1011 105 ST 1x9 850nm ST MM 3 3V Multimode Dual fiber Distance 2km Wavelength 1310 nm Data rate 100Mbps Max Spectral Width 400 0nm FWHM Min Tx Power 19 0 dBm Max Tx Power 14 0 dBm Rx Sensitivity 30 0 dBm Rx Max In Power 14 0 d...

Страница 11: ...the beam directly with optical instruments Failure to observe this warning could result in an eye injury or blindness WARNING Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure WARNING If the media converter is an IEEE802 3 2005 Powered Device PD capable of receiving power via the Media Dependent Interface MDI l...

Страница 12: ...reconnect the twisted pair cable to restart the initialization process Restart the attached device to restart the initialization process Contact Technical Support see Contact Us below YES Go to step 4 4 Is the fiber RX LACT LED lit NO Check the fiber cables for proper connection Verify that the TX and RX cables on the media converter are connected to the RX and TX ports respectively on the other d...

Страница 13: ...covers the original user only and is not transferable This warranty does not cover damage from accident acts of God neglect contamination misuse or abnormal conditions of operation or handling including over voltage failures caused by use outside of the product s specified rating or normal wear and tear of mechanical components If the user is unsure about the proper means of installing or using th...

Страница 14: ...arranted products that are repaired by Transition Networks for a fee will carry a 180 day limited warranty All warranty claims are subject to the restrictions and conventions set forth by this document Transition Networks reserves the right to charge for all testing and shipping incurred if after testing a return is classified as No Problem Found THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTI...

Страница 15: ... spécifiques appropriées In accordance with European Union Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 Transition Networks will accept post usage returns of this product for proper disposal The contact information for this activity can be found in the Contact Us portion of this document CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TE...

Страница 16: ...ión de este equipo deberá llevarse a cabo cumpliendo con las precauciones de seguridad Elsäkerhet OBS Alla nödvändiga försiktighetsåtgärder måste vidtas när denna utrustning används Record of Revisions Rev Date Description of Changes A 7 15 15 Release for SPOEB10xx 105 All pages at Rev A B 12 30 15 Add SPOEB1011 105 and SPOEB1013 105 Update DIP switch and Troubleshooting sections C 11 29 17 Update...