3.2
Installing Units in Rack or on Table
NOTE: StackMaster™ Units are shipped with attached brackets for
standard 19-inch rack installation and with attachable feet for table-top
installation.
3.2.1
Standard 19-Inch Rack Installation
CAUTION: If the StackMaster™ Stack will include an SNMP
Management Unit or a StackMaster™ Unit with an SNMP Management
Board, the SNMP Management Unit or the StackMaster™ Unit with the
SNMP Management Board must be installed at the top of the stack.
Failure to observe this caution will invalidate the SNMP network
management.
NOTE: Rackmount screws and clip nuts are NOT provided with the
StackMaster™ Units.
To install the StackMaster™ Stack in a standard 19-inch rack:
1.
Locate four (4) screws (and clip nuts, if necessary) for each
StackMaster™ Unit to be installed.
2.
Determine the StackMaster™ Unit to be installed at the bottom of
the stack.
3.
Carefully align the StackMaster™ Unit between the 19-inch rack
mounting rails at the lowest installation position.
4.
Install two screws through right front bracket and two screws
through left front bracket, using clip nuts if necessary.
5.
Carefully align the next StackMaster™ Unit above the
StackMaster™ Unit already installed.
6.
Repeat steps 4 and 5 in reverse order until all StackMaster™ Units
have been installed.