Transition Networks, Inc.
IONPS-D-R1 User Guide
33707 Rev. A
Page
7
of
50
MTBF
IONPS-D-R1:
40,00 MIL-HDBK-217F hours
110,000 Bellcore hours
IONDCR-R1:
Greater than 250,000 MIL-HDBK-217F Hours
Greater than 687,500 Bellcore Hours
Dimensions
Width: 8.3” [211 mm] x Depth: 9.0” [229 mm] x Height: 3.4” [86 mm]
Weight
4 lb. (6.35kg) approximately
Operating Temperature
0°C to 50°C (32°F to 122°F )
Storage Temperature
-25°C to 70°C (-13°F 185°F)
Altitude
0-10,000 feet (with de-rating)
Operating Humidity
5% to 95% (non-condensing)
Warranty
Limited Lifetime Warranty
These product specifications are subject to change without further notice.
Primary/Secondary Mode
Only one power supply is needed to power the ION219 chassis; however, there is a second slot to house a
redundant power supply module. If a redundant power supply is used, please note that:
1.
Both power supplies cannot be put in Secondary mode.
2.
If there is only one power supply it will set itself to Primary mode.
3.
The IONPS-D-R1 default setting is Primary mode.
The Primary/Secondary mode is set via the ION software (Web GUI or CLI command). When two IONPS-
D
-R1
modules are installed in an ION chassis, you can select either Primary or Secondary for either or both of the
power supplies via ION software.
The IONPS-D-R1 default setting is Primary mode. A warning message and a control system exist that prevents
both modules from being set to Secondary mode.
Primary
means the IONPS-D-R1 always attempts to provide power to the chassis, and
Secondary
means the
IONPS-D-R1 always attempts to standby, only providing power to the chassis when no other source is providing
sufficient power.
The IONPS-D-R1 is shipped in Primary mode by default, meaning it will always attempt to power the chassis;
if two IONPS-D-R1s are installed in a chassis, they will both attempt to power the chassis, resulting in load-
sharing, with the constant ability for either one to take on the full load of the chassis, should a failure occur.
If you prefer to have primary/secondary operation instead of load-sharing (still maintaining constant fail-over
ability), just change the role of one IONPS-D-R1 from Primary to Secondary.
Power Modules Interoperability Guideline
: If you will be using the older IONPS-A or IONPS-D with the newer
IONPS-A-R1 or IONPS-D-R1 in the same ION219 chassis, then you should place the newer IONPS-A-R1 or IONPS-
D-R1 power supply in the right-hand slot (when facing the back of the ION219 chassis). For more details on the
use of dual power supplies in the ION219 chassis, see the following section.