Command
:
Show IONPS-D-R1 Mode
Syntax
:
show ionpsr1 mode
Description
:
Display the current IONPS-D-R1 primary or secondary mode setting. The default is “primary”.
Configuration Mode indicates whether this is currently configured as the ‘primary’ power supply
or the ‘secondary’ power supply. The secondary power supply is the fail-over or redundant
(backup) power supply.
Example
:
Agent III C1|S22|L1D>
show ionpsr1 mode
IONPS-A/D-R1 Operating as: master
IONPS-A/D-R1 Configured as: master
Agent III C1|S22|L1D>
Command
:
Set IONPS-D-R1 Mode
Syntax
:
set ionpsr1 mode
Description
:
Configures the current IONPS-D-R1 ‘primary’ or ‘secondary’ mode setting. The default is
‘primary’. This is the configured (running) mode that exists in IONPS-D-R1 flash. This value is
always equal to '
ionpsr1OperMode
' except for the case of two IONPS-D-R1s in secondary mode
being inserted in a chassis; one or both of them will be changed to primary mode.
Example
:
Agent III C1|S23|L1D>
show ionpsr1 mode
IONPS-A/D-R1 Operating as: slave
IONPS-A/D-R1 Configured as: slave
Agent III C1|S23|L1D>
set ionpsr1 mode ?
master
slave
Agent III C1|S23|L1D>
set ionpsr1 mode master
Agent III C1|S23|L1D>
show ionpsr1 mode
IONPS-A/D-R1 Operating as: master
IONPS-A/D-R1 Configured as: master
Agent III C1|S23|L1D>
Message
:
The message “
There are 2 IONPS-D-R1 in chassis, you cannot set all of them to Secondary
mode!
” displays on the Web UI. The CLI lets you set master/slave mode, but without limitation.
It allows setting both power supplies to slave.
Command
:
Show Card Type
Syntax
:
show cardtype
Description
:
Display the current slot’s model number.
Example
:
Agent III C1|S23|L1D>
show cardtype
Card type: IONPS-D-R1
Agent III C1|S23|L1D>