CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies

14

24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Contact Us

Technical support

Technical support is available 24 hours a day.
US and Canada:

1-800-260-1312

International:

00-1-952-941-7600

Transition now

Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.

Web-based seminars

Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.

E-Mail

Ask a question anytime by sending an e-mail to our technical support staff at
[email protected]

Address

Transition Networks; 6475 City West Parkway, Minneapolis, MN 55344, U.S.A.
telephone:  952-941-7600; toll free:  800-526-9267; fax:  952-941-2322

Declaration of Conformity

Name of Mfg:

Transition Networks 
6475 City West Parkway, Minneapolis MN 55344 U.S.A.

Model:

CPSMP-210, CPSMP-220 DC Power Supply Module

Part Number(s):

CPSMP-210, CPSMP-220

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the CPSMP-210 and CPSMP-220 to which this declaration

refers is in conformity with the following standards:  CISPR 22:  (1997) w/A1: 2000 Class
A & B; EN 55022: (1998) w/A1: 2000 & A2: 2003 Class A & B; EN 55024:1998 w/A1: 2001

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

Aug  5, 2005_____

Stephen Anderson, Vice-President of Engineering

Date

[email protected] -- Click the “Transition Now” link for live Web chat.

15

Compliance Information

CISPR22/EN55022 Class A & B
CE Mark1
FCC regulations

This equipment has been tested and found to comply with the limits for a Class A & B digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at the user's own
expense.

Canadian regulations

This digital apparatus does not exceed the Class A&B limits for radio noise for digital apparatus set
out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables
aux appareils numériques de la Class A & B prescrites dans le Règlement sur le brouillage
radioélectrique édicté par le ministère des Communications du Canada.

CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies

Содержание CPSMP-210

Страница 1: ...CPSMP 210 48VDC Power Supply CPSMP 220 24VDC Power Supply PointSystem Chassis CPSMC18xx xxx accessory CPSMC19xx 100 accessory User s Manual 33187 C ...

Страница 2: ...trostatic discharge precautions Failure to observe this caution could result in damage to or failure of the power supply WARNING Do not connect the power supply to an external power source before installing it into the chassis Failure to observe this warning could result in an electrical shock even death WARNING The power supply has a provision for grounding Equipment grounding is vital to ensure ...

Страница 3: ...on IMPORTANT All installation and service must be performed by qualified personnel only Read and follow all CAUTION and WARNING notices instructions marked on the product including this manual The CPSMP 210 and CPSMP 220 power supply can replace an existing DC power supply Either can be installed as the redundant power supply in an AC or DC powered PointSystem chassis CAUTION While installing or s...

Страница 4: ...has been disconnected from its external power source To install the power supply in either the CPSMC18xx xxx or the CPSMC19xx 100 PointSystem chassis 1 Slide the power supply ON OFF switch to OFF as shown in Figure 4 Master Slave Management Manual Figure 3 Configuration Switch Positions OFF ON Power Supply ON OFF Switch Power ON LED Terminal Block Figure 4 Power Supply Power ON LED Terminal Block ...

Страница 5: ...F disconnect device open 3 First onnect the power source ground lead to chassis ground See Figure 8 4 Connect the positive DC lead to the terminal block 5 Connect the negative DC lead to the terminal block External Power Cables Power Supply Terminal Block Figure 8 Power Supply Terminal Block and External Power Cable Connections techsupport transition com Click the Transition Now link for live Web ...

Страница 6: ...upply Removal and Installation Management Master Slave Manual Four Position Configuration Switch Instant Failover IFO Board Figure 12 Power Supply configuration Switch techsupport transition com Click the Transition Now link for live Web chat 11 Maintenance continued Configuring the power supply continued 3 Ensure that the module is firmly seated inside the chassis 4 Re install the two 2 6 32 phil...

Страница 7: ...If the power supply module fails or is not working properly isolate and correct the problem by determining the answers to the following questions and then taking the indicated action 1 Is the Power ON LED lit YES Note In a dual power supply chassis make sure that one power supply s configuration switch is set to Master and the second set to Slave See Configuring two power supplies in one chassis p...

Страница 8: ...eclare that the equipment specified above conforms to the above Directive s and Standard s Aug 5 2005_____ Stephen Anderson Vice President of Engineering Date techsupport transition com Click the Transition Now link for live Web chat 15 Compliance Information CISPR22 EN55022 Class A B CE Mark1 FCC regulations This equipment has been tested and found to comply with the limits for a Class A B digita...

Страница 9: ...ht restrictions 2000 2004 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33187 C CPSMP 210 48VDC and CPSMP 220 24VDC Power Supplies ...

Отзывы: