CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies

4

24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Notices

The CPSMP-210 48VDC and CPSMP-220 24VDC power supplies must be
installed by qualified technical personnel only. Transition networks assumes no
responsibility for the improper installation, set up or use of these power supplies.

The information in this user’s guide is subject to change. For the most up-to-date
information, see the user’s guide on-line at www.transition.com.

Figure 1:  Power Supply Components

Description

Transition Networks’ CPSMP-210 48VDC and CPSMP-220 24VDC power supplies
can deliver power or provide optional, redundant DC power to the CPSMC18xx-xxx
and the CPSMC19xx-100 PointSystem chassis.

Power supply component identification

See Figure 1:

Power ON LED 

(green)

External power connector 

(terminal block)

for connecting an external power

source to the power supply

Fuse 

(on the power supply board)

ON/OFF switch, when in the ON position power is supplied to the PointSystem
chassis

Four-position configuration switch 

(located on IFO board)

sets power-supply

functionality 

Chassis ground screw

Fan

Handle for installing and removing the power supply 

Power ON LED 

(green)

(holder not shown)

 Fuse

Four-Position
Configuration Switch

ON/OFF Switch

± Power-Lead Terminal

Block Connectors

Grounding Screw

Fan

Instant Failover (IFO)
Board

Power Supply Board

Handle

[email protected] -- Click the “Transition Now” link for a live Web chat.

5

Installation

I

MPORTANT

All installation and service must be performed by qualified personnel only.

Read and follow all CAUTION and WARNING notices, instructions marked on
the product, including this manual.

The CPSMP-210 and CPSMP-220 power supply can replace an existing DC power
supply. Either can be installed as the redundant power supply in an AC- or DC-
powered PointSystem chassis.

CAUTION: While installing or servicing the power supply, wear a grounding
device and observe all electrostatic discharge precautions. Failure to observe this
caution could result in damage to, or failure of the power supply.

Configuration switch 

Located on the IFO board, the power supply has a four-position configuration switch,
shown in Figure 2. 

Configuration switch-position explanations

The management/manual switch establishes PointSystem software or manual control
of master/slave switch settings for the power supply.

When the management/manual switch is in the 

management

position, power-

supply configuration can be set to master or slave via software.

When the management/manual switch is in the 

manual

position, power-supply

configuration is set manually to master or slave and cannot be changed via
software.

When the master/slave switch is in the 

master

position, the power supply is the

primary power source for the chassis.

When the master/slave switch is in the

slave

position 

(additional power supply)

,

the power supply is used for redundancy 

(failover)

purposes, in the event of a

master power-supply failure. 

Four-Position Configuration Switch

Instant Failover (IFO) Board

Power Supply Board

Management

Manual

Master

Slave

!

Figure 2:  Configuration Switch Location

CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies

Содержание CPSMP-210

Страница 1: ...CPSMP 210 48VDC Power Supply CPSMP 220 24VDC Power Supply PointSystem Chassis CPSMC18xx xxx accessory CPSMC19xx 100 accessory User s Manual 33187 C ...

Страница 2: ...trostatic discharge precautions Failure to observe this caution could result in damage to or failure of the power supply WARNING Do not connect the power supply to an external power source before installing it into the chassis Failure to observe this warning could result in an electrical shock even death WARNING The power supply has a provision for grounding Equipment grounding is vital to ensure ...

Страница 3: ...on IMPORTANT All installation and service must be performed by qualified personnel only Read and follow all CAUTION and WARNING notices instructions marked on the product including this manual The CPSMP 210 and CPSMP 220 power supply can replace an existing DC power supply Either can be installed as the redundant power supply in an AC or DC powered PointSystem chassis CAUTION While installing or s...

Страница 4: ...has been disconnected from its external power source To install the power supply in either the CPSMC18xx xxx or the CPSMC19xx 100 PointSystem chassis 1 Slide the power supply ON OFF switch to OFF as shown in Figure 4 Master Slave Management Manual Figure 3 Configuration Switch Positions OFF ON Power Supply ON OFF Switch Power ON LED Terminal Block Figure 4 Power Supply Power ON LED Terminal Block ...

Страница 5: ...F disconnect device open 3 First onnect the power source ground lead to chassis ground See Figure 8 4 Connect the positive DC lead to the terminal block 5 Connect the negative DC lead to the terminal block External Power Cables Power Supply Terminal Block Figure 8 Power Supply Terminal Block and External Power Cable Connections techsupport transition com Click the Transition Now link for live Web ...

Страница 6: ...upply Removal and Installation Management Master Slave Manual Four Position Configuration Switch Instant Failover IFO Board Figure 12 Power Supply configuration Switch techsupport transition com Click the Transition Now link for live Web chat 11 Maintenance continued Configuring the power supply continued 3 Ensure that the module is firmly seated inside the chassis 4 Re install the two 2 6 32 phil...

Страница 7: ...If the power supply module fails or is not working properly isolate and correct the problem by determining the answers to the following questions and then taking the indicated action 1 Is the Power ON LED lit YES Note In a dual power supply chassis make sure that one power supply s configuration switch is set to Master and the second set to Slave See Configuring two power supplies in one chassis p...

Страница 8: ...eclare that the equipment specified above conforms to the above Directive s and Standard s Aug 5 2005_____ Stephen Anderson Vice President of Engineering Date techsupport transition com Click the Transition Now link for live Web chat 15 Compliance Information CISPR22 EN55022 Class A B CE Mark1 FCC regulations This equipment has been tested and found to comply with the limits for a Class A B digita...

Страница 9: ...ht restrictions 2000 2004 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33187 C CPSMP 210 48VDC and CPSMP 220 24VDC Power Supplies ...

Отзывы: