Cautions and Warnings

3

Definitions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Cautions and warnings in this manual  . . . . . . . . . . . . . . . . . . . . . . . . .3

Description

4

Power supply component identification  . . . . . . . . . . . . . . . . . . . . . . .4
Notices  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Installation

5

Configuration switch   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Configuration switch-postion explanations  . . . . . . . . . . . . . . . . . . . . .5
Configuring two power supplies in one chassis  . . . . . . . . . . . . . . . . .6
Installing the power supply into a PointSystem chassis  . . . . . . . . . . .6
Power source circuit requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Equipment ground  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Disconnect requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Connecting external power  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Redundant 

(failover)

chassis power supply  . . . . . . . . . . . . . . . . . . . . .9

Maintenance

10

Replacing the power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Configuring the power supply  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Replacing the fuse  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Technical Specification

12

Troubleshooting

13

Contact Us

14

Compliance Information

15

[email protected] -- Click the “Transition Now” link for live Web chat.

3

!

!

!

!

!

!

!

Cautions and Warnings

Definitions

Cautions indicate potential damage to equipment.
Warnings indicate potential hazard or injury to people.

Cautions and warnings in this manual

Cautions and Warnings are explained here and placed throughout this manual where
appropriate. 

CAUTION: While installing or servicing the power supply, wear a grounding
device and observe all electrostatic discharge precautions. Failure to observe this
caution could result in damage to, or failure of the power supply.
WARNING: Do not connect the power supply to an external power source before
installing it into the chassis. Failure to observe this warning could result in an
electrical shock, even death. 
WARNING: The power supply has a provision for grounding. Equipment
grounding is vital to ensure safe operation. The installer must ensure that the power
supply is properly grounded during and after installation. Failure to observe this
warning could result in an electric shock, even death.
WARNING: A readily accessible, suitable National Electrical Code (NEC) or
local electrical code approved disconnect device and branch-circuit protector must
be part of the building's installed wiring to accommodate permanently connected
equipment. Failure to observe this warning could result in an electric shock, even
death.
WARNING: Turn the power supply and external power source OFF and ensure
that the power supply is disconnected from the external power source before
performing any maintenance. Failure to observe this warning could result in an
electrical shock, even death.
WARNING: Ensure that the disconnect device for the external power source is
OPEN 

(turned OFF) 

before disconnecting or connecting the power leads to the

power supply. Failure to observe this warning could result in an electric shock,
even death.

!

!

!

!

!

!

CPSMP-210 48VDC and CPSMP-220 24VDC Power Supplies

Содержание CPSMP-210

Страница 1: ...CPSMP 210 48VDC Power Supply CPSMP 220 24VDC Power Supply PointSystem Chassis CPSMC18xx xxx accessory CPSMC19xx 100 accessory User s Manual 33187 C ...

Страница 2: ...trostatic discharge precautions Failure to observe this caution could result in damage to or failure of the power supply WARNING Do not connect the power supply to an external power source before installing it into the chassis Failure to observe this warning could result in an electrical shock even death WARNING The power supply has a provision for grounding Equipment grounding is vital to ensure ...

Страница 3: ...on IMPORTANT All installation and service must be performed by qualified personnel only Read and follow all CAUTION and WARNING notices instructions marked on the product including this manual The CPSMP 210 and CPSMP 220 power supply can replace an existing DC power supply Either can be installed as the redundant power supply in an AC or DC powered PointSystem chassis CAUTION While installing or s...

Страница 4: ...has been disconnected from its external power source To install the power supply in either the CPSMC18xx xxx or the CPSMC19xx 100 PointSystem chassis 1 Slide the power supply ON OFF switch to OFF as shown in Figure 4 Master Slave Management Manual Figure 3 Configuration Switch Positions OFF ON Power Supply ON OFF Switch Power ON LED Terminal Block Figure 4 Power Supply Power ON LED Terminal Block ...

Страница 5: ...F disconnect device open 3 First onnect the power source ground lead to chassis ground See Figure 8 4 Connect the positive DC lead to the terminal block 5 Connect the negative DC lead to the terminal block External Power Cables Power Supply Terminal Block Figure 8 Power Supply Terminal Block and External Power Cable Connections techsupport transition com Click the Transition Now link for live Web ...

Страница 6: ...upply Removal and Installation Management Master Slave Manual Four Position Configuration Switch Instant Failover IFO Board Figure 12 Power Supply configuration Switch techsupport transition com Click the Transition Now link for live Web chat 11 Maintenance continued Configuring the power supply continued 3 Ensure that the module is firmly seated inside the chassis 4 Re install the two 2 6 32 phil...

Страница 7: ...If the power supply module fails or is not working properly isolate and correct the problem by determining the answers to the following questions and then taking the indicated action 1 Is the Power ON LED lit YES Note In a dual power supply chassis make sure that one power supply s configuration switch is set to Master and the second set to Slave See Configuring two power supplies in one chassis p...

Страница 8: ...eclare that the equipment specified above conforms to the above Directive s and Standard s Aug 5 2005_____ Stephen Anderson Vice President of Engineering Date techsupport transition com Click the Transition Now link for live Web chat 15 Compliance Information CISPR22 EN55022 Class A B CE Mark1 FCC regulations This equipment has been tested and found to comply with the limits for a Class A B digita...

Страница 9: ...ht restrictions 2000 2004 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33187 C CPSMP 210 48VDC and CPSMP 220 24VDC Power Supplies ...

Отзывы: