background image

Model 0400

12

3

Ethernet™ Pocket Hub™

5. MAINTENANCE

WARNING: DO NOT, UNDER ANY CIRCUMSTANCES,
open and attempt to repair the 0400 Pocket Hub or power
supply adapter unit.  Failure to observe this warning could
result in personal injury or death from electrical shock.

NOTE: Failure to observe the above warning will immediately void
the warranty.

Fault Isolation

If two network devices fail to communicate through the 0400
Pocket Hub, consider the following:

Are the LEDs described in the previous section functioning
properly?

Do network devices have Link Integrity enabled?

Do network devices communicate when the 0400 Pocket
Hub is not installed between them? 

Is flat or “silver satin” wire used in site internal wiring?

Are internal wiring patch cords, punch down blocks, and
wall jacks properly pinned or configured?

Is the AUI cable unbroken and properly connected?

Are network interface cards properly configured?

Technical Support Contact

For assistance in fault isolation and in maintaining the 0400 Pocket
Hub, contact: 

Technical Support

(800) 260-1312

or your local distributor.

0400 Ethernet Pocket Hub Connectors and
Status LEDs

RJ-45 Connectors

Four (4) 10BaseT RJ-45 jack
connectors are located at
one end of the 0400 Pocket
Hub. The RJ-45  jacks
support connection to
shielded or unshielded 100
ohm twisted pair 10BaseT
cable. 

AUI and Power Supply Adapter Connectors

An external power supply
adapter connector and an
AUI connector are located at
the other end of the 0400
Pocket Hub. The power
supply adapter connector
supplies external power. The
AUI connector supports
connection to 10Base5
through an AUI drop cable.

Status LEDs

Power and Link/Transmit
status LEDs are located at the
side of the 0400 Pocket Hub.
The Power LED indicates
connection to power. The
Link/ Transmit LEDs track
the four 0400 Pocket Hub
connections to 10 BaseT.

RJ-45 Connectors

Female AUI Connector

Power Supply Adapter
Connector

Status LEDs

Содержание 400

Страница 1: ...02 3 Physical Dimensions 4 80 X 2 77 X 0 95 122mm x 70mm x 24mm Power Supply Adapter AC Input PN Requirement Location 3518 120 volts 60 hertz 28 watts USA Canada Mexico 3516 230 volts 50 hertz 28 watts Europe 3514 100 volts 50 60 hertz 28 watts Japan 3517 240 volts 50 hertz 28 watts United Kingdom 3515 240 volts 50 hertz 28 watts Australia DC Output 12 volts at 500 mA maximum MTBF 47 000 hours Env...

Страница 2: ...munikationsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität 10Base2 Cable Specifications The physical characteristics of the 10Base2 cable must meet or exceed ...

Страница 3: ...Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical characteristics of the 10BaseFL cable must meet or exceed IEEE 802 3 10BaseFL specifications 10BaseFL Cable Characteristics Fiber Optic Cable Recommended 62 5 125 µm multimode fiber Optional 100 140 µm multimode fiber 85 125 µm multimode fiber 50 125 µm mult...

Страница 4: ...l not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must follow this procedure for the return of defective items 1 Locate the serial number s of the item s to be returned 2 Determi...

Страница 5: ... WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TRANSITION NETWORKS INC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS RE...

Страница 6: ...ed Are network interface cards properly configured Technical Support Contact For assistance in fault isolation and in maintaining the 0400 Pocket Hub contact Technical Support 800 260 1312 or your local distributor 0400 Ethernet Pocket Hub Connectors and Status LEDs RJ 45 Connectors Four 4 10BaseT RJ 45 jack connectors are located at one end of the 0400 Pocket Hub The RJ 45 jacks support connectio...

Страница 7: ...S The site for the 0400 Ethernet Repeater Hub must provide AC power outlet for each Hub Adequate ventilation Standard environmental conditions Isolation from electrical noise including radio transmitters and broadband amplifiers motors high power electrical lines or fluorescent light fixtures Additionally The twisted pair cables should not run in the same conduit with power line cables Phone lines...

Страница 8: ...ment When connecting Pocket Hubs the transmission path between any two Data Terminating Equipment DTE terminals can consist of no more than five segments To assign segment numbers to cable connections 1 Determine the two terminals in the network which are separated by the greatest number of segments 2 Assign a segment path between the terminals by labeling the cable connected to one of the termina...

Страница 9: ...r 10BaseT wall plate 1 Ethernet Pocket Hub n e t w o r k s T R A N S I T I O N Mpls MN 55344 Straight through 10BaseT Crossover 10BaseT Ensuring Correct 10BaseT Configuration The 10BaseT cable and RJ 45 jacks for Hub to Terminal connections must be configured as straight through The 10BaseT cable and RJ 45 jacks for Hub to Hub connections must be configured as crossover 1 8 RJ 45PLUG RJ 45JACK 1 8...

Страница 10: ...et Hub female AUI connector 1 Locate or build IEEE 802 3 compliant AUI drop cable 2 Connect AUI drop cable male DB 15 connector to the Pocket Hub AUI connector 3 Connect AUI drop cable female DB 15 connector to the AUI port on a transceiver or media attachment unit MAU Connecting10BaseT Cable To connect 10BaseT Cable to Pocket Hub RJ 45 connectors 1 Locate or build 10BaseT cables with the followin...

Отзывы: