background image

Model 0400

8

7

Ethernet™ Pocket Hub™

3. INSTALLATION

NOTE:  0400 Ethernet Pocket Hub Link Integrity cannot be
disabled. All devices connected to the Pocket Hub MUST
have link functions enabled.  

To install the 0400 Ethernet Pocket Hub:

•  Unpack the 0400 Pocket Hub.

Connect 10Base5 Cable to the 0400 Pocket Hub.

Connect 10BaseT Cable to the 0400 Pocket Hub.

Connect the 0400 Pocket Hub to power.

Direction is provided in the pages that follow.

Unpacking the 0400 Pocket Hub

The 0400 Ethernet Pocket Hub packing contents should include the
following:

Item

Part Number

0400 Pocket Hub

E-TBT-HB-0400

Power Supply Adapter

3518, 3517, 3516, 3515, or 3514, 

(depending upon power configuration 
in country where installed)

User’s Guide

7333

Connecting 10Base5  Cable

NOTE: Up to one-hundred 10Base5 connections can be made in one
segment.

To connect 10Base5 Cable to Pocket Hub female AUI connector:

1. Locate or build IEEE 802.3 compliant AUI drop cable.

2. Connect AUI drop cable male DB-15 connector to the

Pocket Hub AUI connector.

3. Connect AUI drop cable female DB-15 connector to the AUI

port on a transceiver or media attachment unit (MAU).

Connecting 10BaseT  Cable

To connect 10BaseT Cable to Pocket Hub RJ-45 connectors:

1. Locate or build 10BaseT cables with the following

characteristics:

802.3 compliant (See page 14)

correct (straight through or crossover) cable configuration

for site installation (See page 6)

male RJ-45 plug connectors installed at both cable ends.

2. Connect male RJ-45 plug connector at one end of 10BaseT

cable to Pocket Hub RJ-45 jack connector.

3. Connect male RJ-45 plug connector at other end of 10BaseT

cable to DTE terminal RJ-45 jack connector (using straight
through 
cable orientation) or to Pocket Hub RJ-45 jack
connector (using crossover cable orientation). NOTE:
Examples are provided in the pages that follow.

Ethernet

Pocket Hub

net

work

s

TR

ANSITIO

N

Mp

ls,

 MN 

55

344

Содержание 400

Страница 1: ...02 3 Physical Dimensions 4 80 X 2 77 X 0 95 122mm x 70mm x 24mm Power Supply Adapter AC Input PN Requirement Location 3518 120 volts 60 hertz 28 watts USA Canada Mexico 3516 230 volts 50 hertz 28 watts Europe 3514 100 volts 50 60 hertz 28 watts Japan 3517 240 volts 50 hertz 28 watts United Kingdom 3515 240 volts 50 hertz 28 watts Australia DC Output 12 volts at 500 mA maximum MTBF 47 000 hours Env...

Страница 2: ...munikationsnetz in den EG Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität 10Base2 Cable Specifications The physical characteristics of the 10Base2 cable must meet or exceed ...

Страница 3: ...Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical characteristics of the 10BaseFL cable must meet or exceed IEEE 802 3 10BaseFL specifications 10BaseFL Cable Characteristics Fiber Optic Cable Recommended 62 5 125 µm multimode fiber Optional 100 140 µm multimode fiber 85 125 µm multimode fiber 50 125 µm mult...

Страница 4: ...l not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must follow this procedure for the return of defective items 1 Locate the serial number s of the item s to be returned 2 Determi...

Страница 5: ... WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TRANSITION NETWORKS INC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS RE...

Страница 6: ...ed Are network interface cards properly configured Technical Support Contact For assistance in fault isolation and in maintaining the 0400 Pocket Hub contact Technical Support 800 260 1312 or your local distributor 0400 Ethernet Pocket Hub Connectors and Status LEDs RJ 45 Connectors Four 4 10BaseT RJ 45 jack connectors are located at one end of the 0400 Pocket Hub The RJ 45 jacks support connectio...

Страница 7: ...S The site for the 0400 Ethernet Repeater Hub must provide AC power outlet for each Hub Adequate ventilation Standard environmental conditions Isolation from electrical noise including radio transmitters and broadband amplifiers motors high power electrical lines or fluorescent light fixtures Additionally The twisted pair cables should not run in the same conduit with power line cables Phone lines...

Страница 8: ...ment When connecting Pocket Hubs the transmission path between any two Data Terminating Equipment DTE terminals can consist of no more than five segments To assign segment numbers to cable connections 1 Determine the two terminals in the network which are separated by the greatest number of segments 2 Assign a segment path between the terminals by labeling the cable connected to one of the termina...

Страница 9: ...r 10BaseT wall plate 1 Ethernet Pocket Hub n e t w o r k s T R A N S I T I O N Mpls MN 55344 Straight through 10BaseT Crossover 10BaseT Ensuring Correct 10BaseT Configuration The 10BaseT cable and RJ 45 jacks for Hub to Terminal connections must be configured as straight through The 10BaseT cable and RJ 45 jacks for Hub to Hub connections must be configured as crossover 1 8 RJ 45PLUG RJ 45JACK 1 8...

Страница 10: ...et Hub female AUI connector 1 Locate or build IEEE 802 3 compliant AUI drop cable 2 Connect AUI drop cable male DB 15 connector to the Pocket Hub AUI connector 3 Connect AUI drop cable female DB 15 connector to the AUI port on a transceiver or media attachment unit MAU Connecting10BaseT Cable To connect 10BaseT Cable to Pocket Hub RJ 45 connectors 1 Locate or build 10BaseT cables with the followin...