6
Figure 3. Free standing footwear
testing with the GTS600K
Figure 4. Footwear testing
with out pedestal
3. Press the test button and hold for 2-3 seconds
4. The green LED labeled “PASS” indicates that the foot
ground is functioning properly.
5. If either the yellow LED “FAIL LO” or the red LED
“FAIL HI” light and audible alarm sound, then check
the foot ground set immediately.
6. Repeat steps 1-5 with opposite foot.
Footwear Testing Cont.