7
Testing Commands
Enter
Reader Response
What It Does
#01 <CR>
#Done <CR/LF>
Switches reader to command mode.
#481
#Done <CR/LF>
Sets operational mode to read ATA
tags.
#40
#Done <CR/LF>
Transmits all tag IDs without regard
for uniqueness.
#6401
#Done <CR/LF>
Turns RF ON.
#00 <CR>
#Done <CR/LF>
Returns reader to data mode.
NOTE
: Encompass 4 Reader will have tag modes specific to your model only
5. If not using Wiegand tags, skip to Step 6. If using
Wiegand tags, configure the reader for Wiegand
operation and connect the Wiegand interface.
Wiegand Testing Commands
Enter
Reader Response
What It Does
#01 <CR>
#Done <CR/LF>
Switches reader to command mode.
#489
#Done <CR/LF>
Sets operational mode to read eATA
data from eGo Plus or eGo tags.
#451
#Done <CR/LF>
Switches reader to Wiegand mode.
#6401
#Done <CR/LF>
Turns RF ON.
#00 <CR>
#Done <CR/LF>
Returns reader to data mode.
Wiegand Interface
Colored Wire Pair
Use This Color
Connect to data wire of
Wiegand device
Blue/Red
Blue
Data0
Red
Data1
Yellow/Black
Yellow or Black
Ground
6. Hold a tag in front of the reader and make sure its data is
read out on the computer screen or on the Wiegand
interface.
7. If desired, input the following commands to return reader
to factory defaults.
Return to Factory Default Commands
Enter
Reader Response
What It Does
#01 <CR>
#Done <CR/LF>
Switches reader to command mode.
#66F
#Done <CR/LF>
Loads all factory default operating
parameters except operating
frequency.
#00 <CR>
#Done <CR/LF>
Returns reader to data mode.