background image

 

12 

Sense Input/Output Cabling Assignments 

Pair 

Pin 

Color 

Signal 

Description 

Typical Function 

Blue/ 
Red 

Blue 

WGND0 

Wiegand data0 

Parking/access control  

 

Red 

WGND1 

Wiegand data1 

Parking/access control  

White/
Red 

White 

Lock 

Tag lock output, 
active-closed 

Testing maintenance 

 

Red 

Lock_RTN 

Tag lock return 

Testing maintenance 

Green/
Red 

Green 

Sense Input0 

Sense Input0 
(loop) 

Loop and presence 
detection 

 

Red 

Sense 
Input0_RTN 

Sense Input0 
return; not isolated 
from signal ground 

Loop and presence 
detection 

Blue/ 
Black 

Blue 

Sense Input1 

Sense Input1 

General-purpose 
sense input, not used 
for detecting presence 

 

Black 

Sense 
Input1_RTN 

Sense Input1 
return; not isolated 
from signal ground 

General-purpose 
sense input, not used 
for detecting presence 

Brown/
Black 

Black 

Sense 
Output0_COM 

Sense Output0 
(tag detect), 
common terminal 

Switched output to 
control gate 

 

Brown 

Sense 
Output0_NO 

Sense Output0 
normally open 
terminal 

Switched output to 
control gate 

Orange/ 
Black 

Black 

Sense 
Output0_COM 

Sense Output0 
(tag detect output), 
common terminal 

Switched sense output 
for any external control 
(light, gate, buzzer, 
etc.) 

 

Orange 

Sense    
Output0_NC 

Sense Output0 
normally closed 
terminal 

Switched sense output 
for any external control 
(light, gate, buzzer, 
etc.) 

Green/
Black 

Black 

Sense Output1_ 
COM 

Sense Output1, 
common terminal 

Switched sense output  

 

Green 

Sense 
Output1_NO 

Sense Output1 
normally open 
terminal 

Switched sense output  

White/ 
Black 

Black 

Sense Output1_ 
COM 

Sense Output1, 
common terminal 

Switched sense output  

 

White 

Sense 
Output1_NC 

Sense Output1 
normally closed 
terminal 

Switched sense output  

Yellow/
Black 

Yellow 

GND 

Logic ground 

Signal ground used 
with RS– 232 and 
Wiegand  

 

Black 

GND 

Logic ground 

Signal ground used 
with RS– 232 and 
Wiegand 

Содержание encompass4

Страница 1: ...TransCore January 2012 412109 008 Driving inefficiencies out of surface transportation through innovative solutions Quick Start Guide...

Страница 2: ...Federal Communications Commission FCC Section 90 239 An FCC license provides the user with the legal authorization to operate the Encompass 4 Reader on the licensed frequencies at the site specified i...

Страница 3: ...Group IAG or combinations of two protocols then the Encompass 4 is the correct reader to use How are the tags formatted Are they ASCII full or half frame or Wiegand tag format If Wiegand then is it 2...

Страница 4: ...lane layout and transaction framing the distance from the entry loop to the reader should normally be no more than about 8 feet with the distance from the reader to the gate arm not exceeding an addit...

Страница 5: ...permanent structures and transient factors in the vicinity that may affect RF signals Metal objects walls and even wet pavement or ice can reflect RF signals degrading system performance Interference...

Страница 6: ...he reader and the computer room Maximum distance for the RS 232 3 wire serial is 50 feet while RS 422 4 wire differential signal maximum distance is up to 4000 feet You may adjust the baud rate to acc...

Страница 7: ...n external junction box 1 Connect all hardware as directed below A Connect the power wires from the cable to the transformer using the color coding as described below Do not apply power to transformer...

Страница 8: ...ns interface is attached and set the properties as follows Bits per second 9600 baud Data bits 8 Parity None Stop bits 1 Flow control None 3 Power up the reader by plugging the transformer into an app...

Страница 9: ...ode 489 Done CR LF Sets operational mode to read eATA data from eGo Plus or eGo tags 451 Done CR LF Switches reader to Wiegand mode 6401 Done CR LF Turns RF ON 00 CR Done CR LF Returns reader to data...

Страница 10: ...mum tag placement is on the side of the windshield nearest the reader for overhead reader placement the optimum tag placement is in the upper center of the windshield 2 Mount the reader on a round pol...

Страница 11: ...ent and make sure that each reader is set up to the proper settings Adjust reader angle power to optimize read zone for each reader Check for interference by each reader or by the environment 7 If usi...

Страница 12: ...10...

Страница 13: ...11...

Страница 14: ...Output0_COM Sense Output0 tag detect common terminal Switched output to control gate U Brown Sense Output0_NO Sense Output0 normally open terminal Switched output to control gate Orange Black V Black...

Страница 15: ...005 Done Set baud rate 9600 1010 Done Use one stop bit 1020 Done Disable parity 40 Done Transmits all tag IDs without regard for uniqueness 450 Done Disable Wiegand mode 451 Done Enable Wiegand mode 4...

Страница 16: ...gand disabled 1 Wiegand enabled Display Wiegand mode status 533 WTI 01 to FF seconds 1 255 in hex Display Wiegand retransmit Interval 570 ATA _ eGo _ SeGo _ IAG _ SORT _ I IT500 ID 64 bits E enabled F...

Страница 17: ...teps The FCC approved range is from 0CF 911 75 MHz to 0EF 919 75 MHz 66F Done Load default operating parameters except RF operating frequency 693F Done Set RF timeout infinite Modulated Frequencies Ap...

Страница 18: ...in a noisy environment or running long cable lengths you may need to reduce the baud rate Long RF cable runs to antennas For the external antenna series Encompass 4 Readers long RF cable runs between...

Страница 19: ...ble is connected to the correct COM port Verify that the reader is in the correct tag read mode 48N Contact Technical Support Strange signal responses come from the Encompass 4 Reader when tested with...

Страница 20: ...Dealer Technical Support at 505 856 8007 Visit us on the Web at www transcore com 2008 TC License Ltd All rights reserved TRANSCORE EGO and ENCOMPASS are registered trademarks of TC License Ltd All o...

Отзывы: