Configuration

The Weighblok has two menus.

The Setup menu, containing most of the indicator's functional Setup parameters, consists of 15 separate menu selections, each with its own
sub-menu of choices.

The User menu, except A5 and A10 containing most of the indicator's serial communication parameters, which not are shown in this
manual.

TO ENTER THE SETUP MENU

1.

Turn the power OFF.

2.

Put Calibration Switch to the Calibration position.

3.

Press the ON key.

4.

The display shows "F1" to indicate that the unit is in Setup menu mode.

5.

To move to a new

F

heading, use TARE or ON to move up or down.

6.

To move to the selection value, press ZERO once.

7.

Increase and decrease the value with PRINT and TARE.

8.

To save the value, press NET.

9.

Press DOT key to go back to parameter number.

10. To go back to normal menu put Calibration Switch to the Normal position.

NOTES ON THE SETUP MENU
There is an F21 sub-menu present that is for FACTORY USE ONLY!

DISPLAY

LCD Enunciator

MEANING

è

0

ç

Better known as the

Center of Zero

enunciator, this light is active whenever the displayed weight is

within

±

0.25 divisions of true zero.

N

Indicates that the indicator is displaying net weight.

G

Indicates that the indicator is displaying gross weight.

T

Indicates that a tare weight has been established in the system.

lb, kg

Indicates the unit of the displayed weight (normally disabled).

bAtt

Indicates a low battery condition. Re-charge the battery or replace if alkaline batteries.

Indicates stable weighing.

Weighblok Enunciator Definitions

ON

PRINT

NET

GROSS

OFF

ZERO

TARE

Содержание WEIGHBLOK

Страница 1: ...Revision 0502 4 2 03 2001 2002 Transcell Technology Inc Contents subject to change without notice Transcell Technology Inc 975 Deerfield Parkway Buffalo Grove IL 60089 Tel 847 419 9180 Fax 847 419 15...

Страница 2: ...Manual Normal Calibration Calibration switch ON PRINT NET GROSS OFF ZERO TARE Communica tions port External power 9 VDC Alkaline batteries The Weighingblock is a robust Scale It is designed for portab...

Страница 3: ...enu while a few other parameters are altered through the User menu The configuration section of the manual explains how to use the five front panel keys to maneuver and save settings in both menus The...

Страница 4: ...ve to the selection value press ZERO once 7 Increase and decrease the value with PRINT and TARE 8 To save the value press NET 9 Press DOT key to go back to parameter number 10 To go back to normal men...

Страница 5: ...accuracy The higher the filter number the greater the accuracy but the slower the response time Choose 4 or 8 unless a very fast response is needed 1 2 4 8 F7 Overload Limit Selects the desired formul...

Страница 6: ...field Parkway 800 503 9180 www transcell net Buffalo Grove IL 60089 847 419 1515 transcell transcell net F6 F7 F8 F9 A10 Auto Power Off Period Selects the auto power off time period in minutes Off Dis...

Страница 7: ...omplete indicator calibration To adjust the max point using the F17 span adjusts procedure 1 Scroll to F 17 then press ZERO to enter span calibration menu 2 The display will momentarily show C 1 for t...

Страница 8: ...erating Mode Indicates a low battery condition Re charge the battery or replace if alkaline batteries Err 0 Span Calibration Mode F17 Keyed in weight value is larger than full scale capacity Use a sma...

Страница 9: ...normal mode Loadcell Connections Check the Loadcell with a universal voltmeter see table The left pin is number 1 Terminal J1 Description Colours Loadcell AG Colours Loadcell 1042 E 1 Out 5 VDC Brown...

Страница 10: ...appears Basic scale use 1 Press ON to start the scale 2 If necessary press ZERO to obtain a weight reading of zero 3 Press OFF to switch off the scale Hold 3 seconds 4 The scale switches off automatic...

Страница 11: ...when filling or discharging One time set up F11 must be 1 and A5 must be 2 normally done when delivered RS 232 PIN NUMBER PIN NAME 2 RXD 3 TXD 5 GND 7 TARGET TTL 5V OV 8 TTL 5V Set the target weight...

Отзывы: