TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Appendix A - Command Set Summary Page 96
In remote loopback configuration one radio of the link
needs to be set as “rf_gen” and the other radio has to be
“rf_refl”.
EXAMPLE
Set loopback mode to if
(trango-config)# loopback if
Loopback Mode: if
SUCCESS
To view current loopback setting:
(trango-config)# loopback
Loopback Mode: if
RELATED
opmode, datapattern
model
SYNTAX
Model
DEFAULT VALUE
N/A
DESCRIPTION
Display system model and serial numbers
EXAMPLE
To display the current model/serial of the system
(trango-config)# model
SYS Model: Apex18-1B
SYS serial ID: 2
RELATED
Version
mse
SYNTAX
Mse <duration>
Duration = 1-99sec
DEFAULT VALUE
Duration = 1sec
DESCRIPTION
Mse command is used to monitor the Mean Square Error
(MSE) of the link. It is used to monitor the link, based on
the specified duration. CLI prompt will not be accessible
while linktest is running