![Trango Systems TrangoLINK APEX 18 Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/trango-systems/trangolink-apex-18/trangolink-apex-18_user-manual_1150515083.webp)
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Appendix A - Command Set Summary Page 81
the “maxatpcpower” and “atpc_step_size”.
When ATPC is turned off, user entered power setting is
restored back.
EXAMPLE
Turn on ATPC
(trango-config)# atpc on
ATPC: on
Check current ATPC configuration
(trango-config)# atpc
ATPC: on
RELATED
atpc_max_power, atpc_step_size, targetrssi, power
atpc_max_power
SYNTAX
atpc_max_power <0-20>
DEFAULT VALUE
Default 17
DESCRIPTION
This command is used to set the upper limit on transmit
power during ATPC.
max atpc power setting is used only when ATPC is on.
EXAMPLE
To set max atpc power
(trango-config)# atpc_max_power 15
ATPC max power: 15.0
Check current ATPC configuration
(trango-config)# atpc_max_power
ATPC max power: 15.0
RELATED
atpc, atpc_step_size, power, targetrssi