![Trango Systems TrangoLINK APEX 18 Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/trango-systems/trangolink-apex-18/trangolink-apex-18_user-manual_1150515082.webp)
TrangoLINK Apex™ 18 User Manual Rev. 1.0 Section: Appendix A - Command Set Summary Page 80
alignment_mode
SYNTAX
alignment_mode < on | off >
DEFAULT VALUE
Off
DESCRIPTION
Alignment mode is used during initial antenna alignment.
When enabled it display the RSSI on the Apex Unit Led at
a higher rate (5/sec) than during normal operation.
ATPC is disabled during alignment_mode. RSSILED
should be ON for alignment_mode
It is recommended to disable alignment_mode during
normal operation.
EXAMPLE
Turn on the alignment_mode
(trango-config)# alignment_mode on
alignment_mode: on
Check current alignment mode setting
(trango-config)# alignment_mode
alignment mode: on
RELATED
rssiled, targetrssi
atpc
SYNTAX
atpc <on | off>
DEFAULT VALUE
Off
DESCRIPTION
Used to enable/disable ATPC
ATPC is used to automatically adjust the remote end
Apex transmit power in order to maintain the desired level
of RSSI (targetrssi) at the local end.
ATPC should be configured on both the radios. If one end
has ATPC on and the other end has ATPC off, then ATPC
will not work.
User cannot change the power when ATPC in turned on.
The system will adjust the power automatically based on
Содержание TrangoLINK APEX 18