background image

10  

32-5053-03

User’s Information

As an 

ENERGY STAR 

Partner, Trane has deter-

mined that this product meets the

 ENERGY STAR 

guidelines for energy effi ciency.

Models Less Than 20 Tons for Residential Use*

Limited Warranty
High Efficiency
Condensing Gas Furnace with 
Whole House Air Cleaner
UX2

(First letter may be preceded by an “A” or “T”)

 

(Parts Only)

This limited warranty is extended by the manufacturer to the original purchaser and to any succeeding owner of the real property to which 
the gas furnace is originally affixed and applies to products purchased and retained for use within the U.S.A. and Canada.

Beginning on January 1, 2010, R-22 refrigerant will no longer be used as a manufacturer-installed refrigerant as required by federal regula-
tion.  Following this date, depending on the availability of any remaining R-22 equipment, indoor model replacements may require that the 
entire system be R-410A compatible.  Outdoor system components and possibly connecting line sets would need to be replaced in order to 
be compatible with indoor units containing R-410A refrigerant.  Expenses associated with replacing system components that are not R-410A 
compatible will not be covered by the terms and conditions of the limited warranty.

The limited warranty period begins when installation is complete and the gas furnace start-up procedure has been properly completed, veri-
fied by installer’s invoice or similar document.  If installation completion and start-up date cannot be verified by installer’s invoice or similar 
document, limited warranty coverage begins six (6) months after the date of manufacture based on the gas furnace serial number.

Limited Warranty

If any part of your gas furnace fails because of a manufacturing defect within five (5) years from the date the limited warranty period begins, 
Warrantor will furnish without charge the required replacement part F.O.B. nearest Parts Distribution point. Any local transportation, related 
service labor, and diagnosis calls, are not included.

Limited Lifetime Warranty

The primary and secondary heat exchanger, when installed to serve a single family residence or single condominium, is warranted to the 
original purchaser for use during his or her lifetime, provided the installation is in the original purchaser’s primary, uninterrupted residence 
from the date the limited warranty period begins until discovery of a defect in the primary heat exchanger or secondary heat exchanger. The 
heat exchanger is warranted to a successor purchaser for a period of twenty (20) years from the date the limited warranty period begins for 
the gas furnace. Warrantor WILL AT ITS OPTION provide either a heat exchanger including secondary heat exchanger without charge F.O.B. 
nearest Parts Distribution point, or allow a credit in the amount of the then current wholesale price of an equivalent heat exchanger toward 
the purchase price of a comparable heating unit. Any local transportation, related service labor, and diagnosis calls, are not included.

This limited warranty does not apply if the gas furnace was purchased direct (i.e. from internet websites or auctions) on an uninstalled 
basis.  Additionally, this limited warranty will not apply unless the gas furnace is: (1) installed by a licensed or qualified HVAC technician, (2) 
applied and installed in accordance with the manufacturer’s recommendations in its Installer’s Guide, and (3) in compliance with all industry 
standards, national, state, and local codes.

This limited warranty does not cover your gas furnace if it is damaged while in your possession; including, but not limited to (1) damage 
caused by unreasonable use of the gas furnace, (2) damage from failure to properly maintain the gas furnace as set forth in the Use and 
Care manual (refer to “Proper Maintenance” section), (3) damage that is not considered a manufacturing defect, such as acts of God, mal-
functions or failures resulting from fire, water, storms, lightning, earthquake, theft, riot, misuse, abuse, increased utility usage costs, or (4) 
performance problems due to improper selection / equipment match-up, installation, or application.

THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILI-
TIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESSED OR IMPLIED, IN LAW OF IN FACT, INCLUDING IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL WARRANTOR BE 
LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or limitation of incidental or 
consequential damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and 
you may also have other rights which vary from state to state.

Parts will be provided by our factory organization through an authorized service organization in your area listed in the yellow pages. If you 
wish further help or information concerning this limited warranty, contact:

Residential Systems
6200 Troup Highway, Tyler, TX 75707
Attention: Consumer Relations

Or visit our website: www.trane.com/residential

TW-1015-3308

* This limited warranty is for residential usage of this equipment and not applicable when this equipment is used for a commercial applica-
tion. A commercial use is any application where the end purchaser uses the product for other than personal, family or household purposes.

Содержание XV90i

Страница 1: ...asoline or other flammable vapors and liquids or combustible materials in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any ele...

Страница 2: ...spiratory skin or eye irritation PRECAUTIONARY MEASURES Avoid breathing fiberglass dust Use a NIOSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting cl...

Страница 3: ...eep this in mind should you choose to remodel the area which contains your furnace If addi tional insulation is added after the furnace is installed the area around the furnace must be inspected to en...

Страница 4: ...p 5 Turn gas cock knob counterclockwise or the toggle switch to ON marker see illustration on this page Turn the external gas cock back to the on position if you expect the furnace to light 6 Replace...

Страница 5: ...FURNACE Have your installer or servicer show you the location if you have any questions UPFLOW FURNACE Manual Main Gas Shut off Valve May Be Located on the Left or Right Side TOP VIEW OF RIGHT SIDE PI...

Страница 6: ...s and filters the air in your home dust and dirt particles build up on the filter Exces sive accumulation can block the airflow forcing the unit to work harder to maintain desired temperatures And the...

Страница 7: ...Lockout 1 Dirty air filtration system 2 Blocked supply or return registers Restricted or plugged furnace Condensate drain 1 Adjust thermostat See operating instructions 2 Replace or reset protective...

Страница 8: ...inates out side the space containing the furnace d The physical support of the furnace should be sound without sagging cracks gaps etc around the base so as to provide a seal between the support and t...

Страница 9: ...he furnace during normal operation 8 CONDENSATE DRAINS If you have a cooling coil in stalled with your furnace condensate drains should be checked and cleaned periodically to assure that conden sate c...

Страница 10: ...tor WILL AT ITS OPTION provide either a heat exchanger including secondary heat exchanger without charge F O B nearest Parts Distribution point or allow a credit in the amount of the then current whol...

Отзывы: