User’s Information

Lighting instructions.

Your furnace does not use a continuously burning pilot 
fl ame. Therefore, manually lighting your furnace is not re-
quired. Your furnace is equipped with an automatic ignition 
system. It  uses a hot surface ignition device that automati-
cally lights the burners each time the thermostat signals the 
furnace to start. 

WARNING

!

SAFETY HAZARD

DO NOT ATTEMPT TO MANUALLY LIGHT THE FURNACE.   
FAILURE TO FOLLOW THIS WARNING MAY RESULT IN 
PERSONAL INJURY, PROPERTY DAMAGE, OR DEATH. 

CAUTION

!

If the furnace is shut down during the cold weather 
months, provisions must be taken to prevent freeze-up of 
all water pipes and water receptacles.

  1.  Please read all safety information in this book before 

operating furnace.

  2.  Set thermostat to lowest setting. Turn off all electric 

power to furnace.

  3.  Remove the furnace front panel to gain access to the 

main gas valve.

  4.  Turn gas cock knob clockwise or the toggle switch 

located on the main gas valve inside the unit  to “OFF” 
position (see illustration on this page). If external gas 
cock is used, turn to “OFF” position (see illustration on 
next page). Allow 5 minutes for any gas within the unit 
to escape. LP gas being heavier than air may require 
forced ventilation. 

 

 

If you smell gas STOP! Follow the “What To Do If 
You Smell Gas” instructions on the front cover of 
this book. If you don’t smell gas, go to next step.

  5.  Turn gas cock knob counterclockwise or the toggle 

switch to “ON” marker (see illustration on this page). 
Turn the external gas cock back to the on position if 
you expect the furnace to light.

  6.  Replace the furnace front access panel.

  7.  Turn on main electrical supply and set thermostat to de-

sired setting. Combustion blower will start and ignition 
device will start to heat up. After approximately 15 sec-
onds main gas valve will open and burners will ignite.

To Start the Furnace

  8.  When thermostat is satisfi ed, main burners will 

extinguish.

  9.  Restore electrical supply panel. If main burners fail 

to ignite, lower Comfort Control setting or disconnect 
electrical supply, wait 5 minutes, raise Comfort Control 
setting above indicated temperature.

 10.  If furnace will not light, turn “OFF” all gas and elec-

tricity to unit and call servicer or gas supplier.

For complete shutdown.

Turn gas cock knob on main gas valve to “OFF” position. 
Disconnect electrical supply to unit.

Whenever your house is to be vacant, arrange to have 
someone inspect your house for proper temperature. If your 
furnace should fail to operate, damage could result, such as 
frozen water pipes.

Flame Roll-out Device.

All models are equipped with a manual resetting rollout 
switch located near the burners. In case of fl ame roll-out, 
the switch trips automatically shutting off all fl ow of gas.  
The switch must be manually reset by pressing the red 
reset button on the top of the switch.

Your furnace may have a “Knob Switch” or a “Toggle Switch” to turn the gas ON or OFF.

Gas Valve  On / Off
Toggle Switch

Gas Valve  On / Off
Toggle Switch

Содержание XV90i

Страница 1: ...asoline or other flammable vapors and liquids or combustible materials in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any ele...

Страница 2: ...spiratory skin or eye irritation PRECAUTIONARY MEASURES Avoid breathing fiberglass dust Use a NIOSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting cl...

Страница 3: ...eep this in mind should you choose to remodel the area which contains your furnace If addi tional insulation is added after the furnace is installed the area around the furnace must be inspected to en...

Страница 4: ...p 5 Turn gas cock knob counterclockwise or the toggle switch to ON marker see illustration on this page Turn the external gas cock back to the on position if you expect the furnace to light 6 Replace...

Страница 5: ...FURNACE Have your installer or servicer show you the location if you have any questions UPFLOW FURNACE Manual Main Gas Shut off Valve May Be Located on the Left or Right Side TOP VIEW OF RIGHT SIDE PI...

Страница 6: ...s and filters the air in your home dust and dirt particles build up on the filter Exces sive accumulation can block the airflow forcing the unit to work harder to maintain desired temperatures And the...

Страница 7: ...Lockout 1 Dirty air filtration system 2 Blocked supply or return registers Restricted or plugged furnace Condensate drain 1 Adjust thermostat See operating instructions 2 Replace or reset protective...

Страница 8: ...inates out side the space containing the furnace d The physical support of the furnace should be sound without sagging cracks gaps etc around the base so as to provide a seal between the support and t...

Страница 9: ...he furnace during normal operation 8 CONDENSATE DRAINS If you have a cooling coil in stalled with your furnace condensate drains should be checked and cleaned periodically to assure that conden sate c...

Страница 10: ...tor WILL AT ITS OPTION provide either a heat exchanger including secondary heat exchanger without charge F O B nearest Parts Distribution point or allow a credit in the amount of the then current whol...

Отзывы: